艺术
美容与健康
工艺
文化与历史
娱乐
环境
食品与饮料
逆向工程
科学
体育
技术
可穿戴设备
Weston Standard Cell
危险
Penny

创建者

Penny

8. 九月 2026DK
2
0
0
0
0

Weston Standard Cell

Every cell before this one was built to give current. This one was built to give a NUMBER, and it held that number so well that for most of the twentieth century the volt itself was defined by a shelf of these jars. The problem Edward Weston solved was not power, it was drift. A Daniell cell is steady enough to run a telegraph and useless as a reference: warm the room and its voltage moves, and you have no way to say by how much. The Clark cell that preceded Weston's was a genuine standard but changed 1.15 mV for every degree, so every reading needed a correction bigger than the precision anyone wanted. US 494,827 "Voltaic Cell", filed 24. November 1891 and granted 4. April 1893, is Weston's answer. One electrode is "an amalgam of cadmium and mercury"; the other is "pure mercury and proto-sulphate of mercury" - what we now write as mercurous sulphate, Hg2SO4. Between them sits a saturated solution of cadmium sulphate. The patent's own claim is not about voltage at all: it claims a cell "whose electromotive force is practically independent of temperature changes". It gives 1.018636 V at 20 degrees C and moves roughly 40 microvolts per degree - about 40 parts per million, some thirty times flatter than the Clark cell, which it replaced as the standard in 1905. Weston's own vessel is two cylindrical glass tubes joined by a cross tube, platinum wires sealed through the bottom of each, the whole thing bedded in a wooden block inside a brass case and filled with a beeswax, rosin and linseed oil compound - a jar built to be left alone. Its limit is the same as its virtue. Draw any real current and you move the number you came to read; the cell is a reference and never a supply. National laboratories retired it in 1990 for the Josephson effect, which is at least four orders of magnitude steadier and contains no mercury. Cadmium, mercury and mercurous sulphate are all toxic and this build is gated for that reason. Read the last two steps before the first: one of them tells you how to use a standard cell without destroying it, and the other tells you what to build instead if you only want the measurement.
高级
3 hours, then a week standing still

危险内容

此蓝图包含危险操作。请登录并在账户设置中启用危险内容,以查看分步说明。

CC0 公共领域

此蓝图以 CC0 协议发布。你可以自由复制、修改、分发和使用此作品,无需征得许可。

通过购买蓝图中的产品支持创客,他们将获得 创客佣金 (由供应商设定),或创建此蓝图的新版本并将其作为连接包含在你自己的蓝图中以分享收入。

讨论

(0)

登录 加入讨论

加载评论中...