Lactide: Lactic Acid Condensed and Cracked under Vacuum, Recrystallised
Lactide is the ring-shaped double molecule of lactic acid, the monomer from which PLA is made. Schneider's du Pont patent (US 2,703,316, 1955) drives the water out of lactic acid, condenses it under vacuum to a syrupy low polymer, then heats that to 200–250 °C at 8–10 mm so that lactide distils off. For a tough plastic it must be very pure: recrystallise it from ethyl acetate until it melts at 120 °C or higher (best 123–125 °C).
The picture: our diagram.
Erfahren
1–2 days
Anweisungen
1
1
Drive off the water
Drive off the water
Distil the lactic acid at atmospheric pressure at 120–130 °C until nearly all the water of dilution has gone.
Materialien für diesen Schritt:
Milchsäure (technisch)1 StückBenötigte Werkzeuge:
Rundkolben
Kondensatorschlange
Heizplatte
Ölbad
Laborthermometer2
2
Condense under vacuum
Condense under vacuum
Continue distilling under 17–35 mm of mercury. Water of esterification comes off and the acid becomes a syrupy low polymer (polylactic acid).
Benötigte Werkzeuge:
Vakuumpumpe
Vakuummeter
Kühlfalle
Ölbad
Laborthermometer3
3
Crack to lactide
Crack to lactide
Lower the pressure to 8–10 mm and raise the temperature to 200–250 °C. Lactide distils at 130–140 °C (10–13 mm) and sets to a soft crystalline solid.
Benötigte Werkzeuge:
Vakuumpumpe
Vakuummeter
Kondensatorschlange
Ölbad
Laborthermometer
Hitzebeständige Handschuhe4
4
Recrystallise from ethyl acetate
Recrystallise from ethyl acetate
Recrystallise the crude lactide from ethyl acetate, filter and dry. Repeat: in the patent the melting point rose from 114–115 °C after the first crystallisation to 118, 123–124 and 124–125 °C after the fourth.
Benötigte Werkzeuge:
Ethylacetat
Hitzebeständiges Becherglas
Heizplatte
Büchnertrichter (Porzellan)
Filterpapier
Chemikalienschutzbrille5
5
Check the melting point
Check the melting point
Put a few crystals in a capillary tube and warm slowly. Lactide melting at 120 °C or above is fit for making PLA; below 120 °C it gives a brittle polymer.
Benötigte Werkzeuge:
Glas-Kapillarrohr
Laborthermometer
ÖlbadMaterialien
1- 1 StückPlatzhalter
Benötigte Werkzeuge
15- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- 1 vendor sell this, none ship to you yetPlatzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
- Platzhalter
Dieser Bauplan stellt her
Verwandte Blueprints
Diese Blueprints teilen Wissen — Techniken, Materialien oder Prinzipien
CC0 Gemeinfrei
Dieser Blueprint ist unter CC0 veröffentlicht. Sie dürfen dieses Werk für jeden Zweck frei kopieren, ändern, verbreiten und verwenden, ohne um Erlaubnis zu fragen.
Unterstützen Sie den Maker, indem Sie Produkte über seinen Blueprint kaufen, wo er eine Maker-Provision von Anbietern festgelegt, verdient. Oder erstellen Sie eine neue Iteration dieses Blueprints und verbinden Sie ihn in Ihrem eigenen Blueprint, um Einnahmen zu teilen.