Spring Scale Calibrated with Known Weights
Penny

Creado por

Penny

11. octubre 2026DK
38
0
0
0
0

Spring Scale Calibrated with Known Weights

A spring scale, or newton meter, is a spring fixed at one end with a hook at the other. By Hooke's law the stretch grows in step with the force, so the marks on its scale are evenly spaced. This one is built in a clear tube with a paper scale and calibrated with known weights: on Earth a 100 g mass pulls with about 0.98 N (100 g × 9.81 m/s²). The sizes here are ours: a tube about 20 cm long and a light extension spring that stretches clearly under 1 kg. Do not load it past the heaviest calibration weight: an overstretched spring stays longer and the scale is lost.
Principiante
2 hours

Instrucciones

1

Make the hooks

Bend two pieces of steel wire with round-nose pliers: one with a loop at each end to hang the spring from the top plug, one long rod with a loop at the top and a hook at the bottom.

Materiales para este paso:

Alambre de aceroAlambre de acero0.4 m

Herramientas necesarias:

Alicates de punta redondaAlicates de punta redonda
2

Plug the tube

Push the top wire through one cork disc and glue the disc into the top of the tube. Make a hole in the second disc for the rod to slide through and glue it into the bottom.

Materiales para este paso:

Tubo acrílico (transparente)Tubo acrílico (transparente)1 pieza
Disco pequeño de corchoDisco pequeño de corcho2 piezas
Pegamento instantáneo (cianoacrilato)Pegamento instantáneo (cianoacrilato)1 pieza

Herramientas necesarias:

Cúter de precisiónCúter de precisión
3

Hang the spring

Hook the spring to the top loop and the rod's top loop to the spring, so the rod hangs out through the bottom plug. The lower end of the spring is the pointer.

Materiales para este paso:

Muelle de tracciónMuelle de tracción1 pieza
4

Fit the scale

Glue a strip of graph paper along the outside of the tube and mark zero at the spring's lower end with nothing hanging.

Materiales para este paso:

Papel milimetradoPapel milimetrado1 pieza

Herramientas necesarias:

Rotulador permanenteRotulador permanente
5

Calibrate

Hang 100 g, 200 g and so on up to 1 kg, marking the pointer each time; each 100 g is about 0.98 N. The marks should be evenly spaced; check that the pointer returns to zero when unloaded.

Herramientas necesarias:

Juego de pesas de calibraciónJuego de pesas de calibración

Materiales

6

Herramientas requeridas

4

Blueprints relacionados

Estos blueprints comparten conocimiento — técnicas, materiales o principios

CC0 Dominio público

Este Blueprint se publica bajo CC0. Eres libre de copiar, modificar, distribuir y usar este trabajo para cualquier propósito, sin pedir permiso.

Apoya al Maker comprando productos a través de su Blueprint, donde gana una Comisión del Maker establecida por los vendedores, o crea una nueva iteración de este Blueprint e inclúyela como conexión en tu propio Blueprint para compartir ingresos.

Discusión

(0)

Iniciar sesión para unirte a la discusión

Cargando comentarios...