Hot-Wire Anemometer

A cup anemometer counts revolutions, so it tells you the average wind over some seconds and nothing about what happened inside them. Turbulence, gusts, the structure of a boundary layer — all of it is averaged away by the cups' own inertia. The hot-wire anemometer has almost no inertia at all: a wire a few microns thick is heated electrically, moving air cools it, and the cooling changes its resistance. The wire responds in microseconds because there is essentially nothing to it. Louis Vessot King published the governing relation in 1914, and the instrument became the tool that made turbulence measurable — you can watch the velocity fluctuate thousands of times a second at a single point in a flow.
Avancé
4 hours 30 minutes

Consignes

1

Mount the finest wire you can handle

Thin is the entire design goal, and it makes the sensor fragile by necessity.

  1. Make a fork from two stiff wire prongs about 3 mm apart, mounted on an insulating handle.
  2. Stretch the finest available nichrome or tungsten wire between the prongs and solder or clamp it.
  3. Keep the free span short and straight, with no kinks.
  4. Measure its cold resistance with a four-wire meter.

Thinner is faster and more fragile in the same proportion. A fine wire has almost no thermal mass, so it follows velocity changes almost instantly — but a research probe uses wire five microns across and is destroyed by a speck of dust. What you can build by hand is coarser and slower, and that trade is the instrument's whole character.

Handle it only by the fork. The wire itself cannot survive being touched, and a probe is normally treated as a consumable rather than a repairable item.

Matériaux pour cette étape :

Enamelled Copper WireEnamelled Copper Wire1 rouleau
Copper Wire (20 Gauge)Copper Wire (20 Gauge)1 rouleau
Acrylic RodAcrylic Rod1 pièce

Outils nécessaires :

Digital Multimeter (Lab Grade)Digital Multimeter (Lab Grade)
File SetFile Set
Digital Caliper 6-InchDigital Caliper 6-Inch
Bench Vise (4-inch, Cast Iron)Bench Vise (4-inch, Cast Iron)
2

Heat it in a bridge and watch air cool it

The Wheatstone bridge appears for the third time in this batch, now sensing heat loss.

  1. Put the wire in one arm of a bridge with three fixed resistors.
  2. Drive the bridge hard enough that the wire runs distinctly above ambient — warm, not glowing.
  3. Balance the bridge in still air.
  4. Blow gently across the wire and watch the bridge output swing.
  5. Vary the airspeed and note the output changes with it.

Moving air steals heat, the wire cools, its resistance falls, the bridge unbalances. That chain of four physical steps is the whole instrument. Note that the same bridge circuit measured temperature in the resistance thermometer and will measure force in the strain gauge — one circuit, three completely different measurands, because all three sensors work by changing a resistance.

Do not overheat the wire. Run it too hot and it oxidises, changes resistance permanently and eventually burns through — and the calibration is gone the moment it changes.

Matériaux pour cette étape :

1/4W Resistor Kit (600pcs, 30 Values)1/4W Resistor Kit (600pcs, 30 Values)1 kit
Adjustable Bench Power Supply (30V/5A)Adjustable Bench Power Supply (30V/5A)1 pièce

Outils nécessaires :

Digital Multimeter (Lab Grade)Digital Multimeter (Lab Grade)
Analog MultimeterAnalog Multimeter
StopwatchStopwatch
3

Calibrate against the pitot tube

Use the instrument from earlier in this batch as your velocity reference.

  1. Mount the hot wire and the pitot tube side by side in the same airflow.
  2. Set several airspeeds and record both readings at each.
  3. Plot bridge output against pitot-derived velocity.
  4. Note the curve's shape.
The relationship is strongly non-linear — heat loss rises roughly with the square root of velocity, which is King's law, published in 1914. That means the instrument is very sensitive at low speeds where the pitot tube fails completely, and progressively less sensitive as speed rises. The two instruments have opposite sensitivity curves, which is exactly why a wind tunnel uses a pitot for mean speed and a hot wire for the fluctuations.

Matériaux pour cette étape :

Graph PaperGraph Paper1 pad

Outils nécessaires :

Digital Multimeter (Lab Grade)Digital Multimeter (Lab Grade)
StopwatchStopwatch
Digital Caliper 6-InchDigital Caliper 6-Inch
4

See the turbulence the cup anemometer hides

The reason this instrument exists, demonstrated against its sibling.

  1. Set up a steady fan flow and hold the hot wire in it, watching the output on a fast meter or scope.
  2. Note the reading fluctuating rapidly even though the fan speed is constant.
  3. Now put a rod or a mesh upstream and observe the fluctuations grow.
  4. Compare with a cup anemometer in the same place, which shows a steady average.
The fluctuations are turbulence — real velocity variations at a point, thousands of times a second. The cup anemometer's rotor cannot follow them and reports only the mean. Both instruments are correct; they answer different questions. Aerodynamics as a quantitative science depends on being able to see the fluctuations, which is why the hot wire mattered so much.

Outils nécessaires :

Digital Multimeter (Lab Grade)Digital Multimeter (Lab Grade)
Analog MultimeterAnalog Multimeter
StopwatchStopwatch
5

Constant current versus constant temperature, and history

Louis Vessot King published his analysis of convective heat loss from a fine cylinder in 1914 at McGill University, giving the relationship still called King's law. The instrument existed in cruder forms before, but a usable calibration is what turns a phenomenon into a measurement.

The important refinement came later: the constant-temperature anemometer. In the simple version built here the current is fixed and the wire's temperature varies with flow — but the wire then has to heat and cool, and that takes time, limiting the frequency response. In the constant-temperature version a feedback amplifier instantly adjusts the current to hold the wire at a fixed resistance, and the CURRENT becomes the output. Because the wire never changes temperature, its thermal inertia stops mattering and the response extends to tens of kilohertz. It is a lovely example of feedback removing a physical limitation rather than working around it.

Against its sibling in this catalogue: the Robinson cup anemometer is robust, needs no power, works outdoors for decades and gives a reliable mean wind speed. The hot wire is delicate, needs electronics, cannot survive rain or dust, and sees things nothing else can see. Weather station versus wind tunnel — same quantity, completely different instruments, chosen by what you need to know about it.

Its honest limits: extreme fragility; contamination by dust that changes the heat transfer and hence the calibration; it senses the magnitude of flow but not its direction, so multiple wires at angles are needed for that; and it responds to temperature as well as velocity, so ambient changes must be compensated.

Matériaux

6

Outils requis

6

Blueprints liés

Ces blueprints partagent des connaissances — techniques, matériaux ou principes

CC0 Domaine public

Ce blueprint est publié sous CC0. Vous êtes libre de copier, modifier, distribuer et utiliser ce travail pour tout usage, sans demander la permission.

Soutenez le Maker en achetant des produits via son Blueprint où il perçoit une Commission Maker définie par les Vendeurs, ou créez une nouvelle itération de ce Blueprint et incluez-le comme connexion dans votre propre Blueprint pour partager les revenus.

Commentaires

(0)

Se connecter pour participer à la discussion

Chargement des commentaires...