LIST
FEGURÐ OG VELLÍÐAN
HANDVERK
MENNING OG SAGA
SKEMMTUN
UMHVERFI
MATUR OG DRYKKUR
ÖFUGVERKFRÆÐI
VÍSINDI
ÍÞRÓTTIR
TÆKNI
KLÆÐANLEG TÆKNI
Multi-Conductor Cable: Cotton-Covered, Waxed and Twisted
Penny

Búin til af

Penny

14. október 2026DK
15
0
0
0
0

Multi-Conductor Cable: Cotton-Covered, Waxed and Twisted

A cable of several insulated wires in one bundle, such as the four leads of a strain-gauge bridge. Each copper wire is wrapped in cotton thread and soaked in beeswax, then the wires are twisted together and covered again.
Byrjandi
An afternoon

Leiðbeiningar

1

Cut the conductors

Cut one copper wire per conductor (four for a bridge), a little longer than the cable.

Efni fyrir þetta skref:

KoparvírKoparvír4 length

Nauðsynleg verkfæri:

VírstrípariVírstrípari
2

Wrap each wire in cotton

Clamp one end in the vise and the other in the hand drill's chuck, keeping it taut. Wind cotton thread on in a close spiral with no gaps, then a second layer the opposite way.

Efni fyrir þetta skref:

BómullarþráðurBómullarþráður1 as required

Nauðsynleg verkfæri:

SkrúfstykkiSkrúfstykki
HandborHandbor
SkæriSkæri
3

Soak in beeswax

Melt beeswax in a double boiler and draw each covered wire slowly through it. Wipe off the excess and let it set.

Efni fyrir þetta skref:

BýflugnavaxBýflugnavax1 as required

Nauðsynleg verkfæri:

VatnsbaðspotturVatnsbaðspottur
HitaplataHitaplata
4

Twist them together

Lay the covered wires side by side, clamp one end and twist them together evenly with the drill.

Nauðsynleg verkfæri:

SkrúfstykkiSkrúfstykki
HandborHandbor
5

Cover the bundle

Wind an outer layer of cotton over the twisted bundle and wax it again.

Efni fyrir þetta skref:

BómullarþráðurBómullarþráður1 as required
BýflugnavaxBýflugnavax1 as required

Nauðsynleg verkfæri:

SkrúfstykkiSkrúfstykki
VatnsbaðspotturVatnsbaðspottur
HitaplataHitaplata
6

Test it

Strip the ends. With a multimeter check each wire end to end, and check that no two wires touch.

Nauðsynleg verkfæri:

VírstrípariVírstrípari
FjölsviðsmælirFjölsviðsmælir
7

Limits

Cotton insulation is only good for low temperatures, up to about 105 °C (Wikipedia, Magnet wire), and for dry places and low voltages such as instrument leads. The method is general workshop practice, ours.

Efni

3

Nauðsynleg verkfæri

7

CC0 opinbert ríki

Þessi teikning er gefin út undir CC0. Þér er frjálst að afrita, breyta, dreifa og nota þetta verk í hvaða tilgangi sem er, án þess að biðja um leyfi.

Studdu smiðinn með því að kaupa vörur í gegnum teikningu hans þar sem hann fær þóknun smiða sem seljendur ákvarða, eða búðu til nýja endurskoðun á þessari teikningu og tengdu hana sem tengingu í þinni eigin teikningu til að deila tekjum.

Umræða

(0)

Skrá inn til að taka þátt í umræðunni

Hleður athugasemdum...