Spring Scale Calibrated with Known Weights
Penny

Creato da

Penny

11. ottobre 2026DK
35
0
0
0
0

Spring Scale Calibrated with Known Weights

A spring scale, or newton meter, is a spring fixed at one end with a hook at the other. By Hooke's law the stretch grows in step with the force, so the marks on its scale are evenly spaced. This one is built in a clear tube with a paper scale and calibrated with known weights: on Earth a 100 g mass pulls with about 0.98 N (100 g × 9.81 m/s²). The sizes here are ours: a tube about 20 cm long and a light extension spring that stretches clearly under 1 kg. Do not load it past the heaviest calibration weight: an overstretched spring stays longer and the scale is lost.
Principiante
2 hours

Istruzioni

1

Make the hooks

Bend two pieces of steel wire with round-nose pliers: one with a loop at each end to hang the spring from the top plug, one long rod with a loop at the top and a hook at the bottom.

Materiali per questo passaggio:

Filo di acciaioFilo di acciaio0.4 m

Strumenti necessari:

Pinze a becchi tondiPinze a becchi tondi
2

Plug the tube

Push the top wire through one cork disc and glue the disc into the top of the tube. Make a hole in the second disc for the rod to slide through and glue it into the bottom.

Materiali per questo passaggio:

Tubo acrilico (trasparente)Tubo acrilico (trasparente)1 pezzo
Piccolo disco di sugheroPiccolo disco di sughero2 pezzi
Colla istantanea (cianoacrilato)Colla istantanea (cianoacrilato)1 pezzo

Strumenti necessari:

Taglierino di precisioneTaglierino di precisione
3

Hang the spring

Hook the spring to the top loop and the rod's top loop to the spring, so the rod hangs out through the bottom plug. The lower end of the spring is the pointer.

Materiali per questo passaggio:

Molla di trazioneMolla di trazione1 pezzo
4

Fit the scale

Glue a strip of graph paper along the outside of the tube and mark zero at the spring's lower end with nothing hanging.

Materiali per questo passaggio:

Carta millimetrataCarta millimetrata1 pezzo

Strumenti necessari:

Pennarello indelebilePennarello indelebile
5

Calibrate

Hang 100 g, 200 g and so on up to 1 kg, marking the pointer each time; each 100 g is about 0.98 N. The marks should be evenly spaced; check that the pointer returns to zero when unloaded.

Strumenti necessari:

Set di pesi di taraturaSet di pesi di taratura

Materiali

6

Strumenti richiesti

4

Blueprint correlati

Questi blueprint condividono conoscenze — tecniche, materiali o principi

CC0 Pubblico dominio

Questo progetto è rilasciato sotto CC0. Sei libero di copiare, modificare, distribuire e utilizzare quest'opera per qualsiasi scopo, senza chiedere permesso.

Supporta il Maker acquistando prodotti tramite il suo progetto dove guadagna una Commissione Maker stabilita dai venditori, oppure crea una nuova iterazione di questo progetto e includilo come collegamento nel tuo progetto per condividere i ricavi.

Commenti

(0)

Accedi per partecipare alla discussione

Caricamento commenti...