ARTE
BELLEZZA E BENESSERE
MESTIERE
CULTURA E STORIA
DIVERTIMENTO
AMBIENTE
CIBO E BEVANDE
INGEGNERIA INVERSA
SCIENZE
SPORT
TECNOLOGIA
INDOSSABILI
Venturi Meter
Penny

Creato da

Penny

20. agosto 2026DK
1
0
0
0
0

Venturi Meter

A way to measure how much water is flowing through a pipe without putting anything in its path. Narrow the pipe smoothly, and the water must speed up to get through; speeding up costs pressure, so the pressure at the narrow throat drops by an amount that depends only on the flow rate and the geometry. Measure that pressure difference and you know the flow. Clemens Herschel patented it in the United States as 381,373 on 17 April 1888, under the plain title Apparatus for measuring the quantity of water flowing through a pipe, and named it after Giovanni Battista Venturi, who had studied the effect in tapered tubes ninety years earlier. Because nothing obstructs the bore, it does not wear out and barely costs any pressure overall — which is why waterworks still use them.
Principiante
45 minutes

Istruzioni

1

Build the constriction

A wide section, a smoothly narrowing cone, a short throat, then a gentle widening.

  1. Use pipe of one diameter with a reducer to a smaller throat.
  2. Make the entry cone short and the exit cone long and gradual.
  3. Keep the inside smooth — burrs cause turbulence and spoil the reading.
The long gentle exit is not decoration. It lets the water slow down and recover most of its pressure, which is why a Venturi wastes far less energy than an orifice plate doing the same job.

Materiali per questo passaggio:

PVC Pipe (50 mm)PVC Pipe (50 mm)1 length
2

Fit the pressure tappings

Two vertical clear tubes turn pressure into a height you can read with a ruler.

  1. Drill one small tapping in the wide section and one at the throat.
  2. Fit clear vertical tubes into both, sealed so they do not leak.
  3. Mount a ruler behind them.
Drill square to the wall and deburr the inside. A tapping with a lip sticking into the flow reads its own turbulence instead of the static pressure you want.

Materiali per questo passaggio:

Rubber Tubing (Lab Grade)Rubber Tubing (Lab Grade)1 length
Steel RulerSteel Ruler1 pezzo
3

Run water and read the difference

Start the flow and let the levels settle.

  1. Run water through at a steady rate.
  2. Read the height in each tube.
  3. Record the difference, Δh, in metres.
The throat level sits LOWER. Faster water has lower pressure — that is Bernoulli's principle, and here it is visible as two different water heights rather than an equation.
4

Calculate the flow

Geometry plus one measured height gives the flow rate.

  1. Measure the two internal diameters and compute areas A₁ and A₂.
  2. Apply: Q = A₂ × √( 2gΔh / (1 − (A₂/A₁)²) )
  3. g = 9.81 m/s². Q comes out in m³/s.
Nothing about the fluid's density appears, because it cancels when the manometer holds the same liquid that is flowing. The meter measures volume flow from geometry and a height alone.
5

Check it against a bucket

A calculation you have not checked is a guess. Catch the water and time it.

  1. Divert the outflow into a container for a measured number of seconds.
  2. Measure the volume collected.
  3. Q_actual = volume / time, and compare with the calculated Q.
Your measured flow will come out slightly BELOW the calculation, typically 2-5% low. That ratio is the discharge coefficient C_d, and it accounts for friction the ideal equation ignores. Real meters are calibrated for exactly this — finding it yourself is the point of the exercise.

Materiali per questo passaggio:

StopwatchStopwatch1 pezzo
Borosilicate BeakerBorosilicate Beaker1 pezzo
6

History and context

Clemens Herschel was an American hydraulic engineer working on water supply at Holyoke, Massachusetts, where mills bought water by the quantity and needed it measured fairly. Existing meters obstructed the pipe, wore out, or lost too much pressure. His patent, US 381,373 of 17 April 1888, describes an apparatus for measuring the quantity of water flowing through a pipe using the sucking action at the narrow section of a tapered tube.

He named it after someone else. Giovanni Battista Venturi, an Italian physicist, had investigated flow through tapered tubes in 1797 and described the pressure effect, but he built no meter and proposed no measurement method. Herschel turned the observation into an instrument and gave the instrument Venturi's name — an unusually generous piece of attribution in patent history.

Where it went: waterworks, sewage plants and process industries adopted it for large flows where a permanent pressure loss would be expensive. The same physics appears in the carburettor, where the pressure drop at a throat draws fuel into the air stream, and in the filter pump on a laboratory bench.

Its weakness: the pressure difference goes as the SQUARE of the flow, so at low flow rates Δh becomes very small and hard to read accurately. A Venturi sized for full flow is a poor meter at a trickle, which is why plants size them for the range they actually expect.

Materiali

5

Blueprint correlati

Questi blueprint condividono conoscenze — tecniche, materiali o principi

CC0 Pubblico dominio

Questo progetto è rilasciato sotto CC0. Sei libero di copiare, modificare, distribuire e utilizzare quest'opera per qualsiasi scopo, senza chiedere permesso.

Supporta il Maker acquistando prodotti tramite il suo progetto dove guadagna una Commissione Maker stabilita dai venditori, oppure crea una nuova iterazione di questo progetto e includilo come collegamento nel tuo progetto per condividere i ricavi.

Commenti

(0)

Accedi per partecipare alla discussione

Caricamento commenti...