Dial Indicator
A micrometer answers “how big is this?”. A dial indicator answers a different and often more useful question: “how much has this moved?” It does not measure size at all. It measures deviation.
US 283,627, “Improvement in Gages”, John Logan of Waltham, Massachusetts, filed 15 May 1883 and granted 21 August 1883. The claim is mechanical amplification: a tiny movement of a plunger is geared up into a large sweep of a pointer, so the eye reads a distance it could never see directly.
Waltham is not a coincidence. This is watchmaking country, and a watch is a machine for turning small regular motions into readable ones. Logan applied the movement-maker's habit of mind to the machine shop.
手順
Read the claim before you build
Read the claim before you build
Logan claims amplification. Write down the difference between measuring a size and measuring a deviation — the two need different instruments.
Handle a real indicator
Handle a real indicator
Press the plunger of the dial indicator gently and watch the needle. Estimate how many times larger the needle's travel is than the plunger's.
必要な工具:
Dial IndicatorBuild a lever amplifier
Build a lever amplifier
Cut a 200 mm card strip. Pin it to the board 20 mm from one end with a screw. The long end now moves nine times as far as the short end.
このステップの材料:
Graph Paper1 枚
#6-32 Machine Screw1 個必要な工具:
Sharp ScissorsCalculate your amplification ratio
Calculate your amplification ratio
Ratio = long arm divided by short arm. Write it down before you test it, then check it.
このステップの材料:
Graph Paper1 枚必要な工具:
Steel Ruler (30cm)Feed a known input with a feeler leaf
Feed a known input with a feeler leaf
Slide a 0.05 mm feeler leaf under the short end. Measure how far the long end rises.
必要な工具:
Feeler Gauge Set
Steel Ruler (30cm)Check measured against predicted
Check measured against predicted
Compare the measured rise with ratio × 0.05 mm. Any shortfall is lost motion in your pivot — the enemy Logan's gearing had to defeat.
このステップの材料:
Graph Paper1 枚Build a scale for the long end
Build a scale for the long end
Mark a card scale where the long end sweeps, graduated in millimetres. Each millimetre now stands for a fraction of one at the input.
このステップの材料:
Graph Paper1 枚必要な工具:
Steel Ruler (30cm)
Permanent MarkerMeasure the whole feeler set
Measure the whole feeler set
Run every leaf from 0.05 to 0.50 mm through your amplifier, recording the output each time.
このステップの材料:
Graph Paper1 枚必要な工具:
Feeler Gauge SetPlot input against output
Plot input against output
Plot the pairs. A good instrument gives a straight line. Curvature means your ratio changes with position — a real and common defect.
このステップの材料:
Graph Paper1 枚Find the backlash
Find the backlash
Approach one leaf thickness from below, then from above. The two readings differ. That gap is backlash, and it is why indicators are read in one direction only.
必要な工具:
Feeler Gauge SetMeasure flatness with the real indicator
Measure flatness with the real indicator
Rest the indicator on the surface plate and sweep it across the board's face. Watch the needle wander. You are seeing the board's error, magnified.
このステップの材料:
Flat Wooden Board1 個必要な工具:
Dial Indicator
Surface PlateMeasure run-out on a rod
Measure run-out on a rod
Roll the brass rod under the indicator tip. The needle sweep is the rod's out-of-roundness — invisible to the eye, obvious to the dial.
必要な工具:
Dial Indicator
Brass RodTry the same job with a micrometer
Try the same job with a micrometer
Attempt step 11 with the micrometer instead. It is slow and awkward, because it answers the wrong question. Two instruments, two jobs.
必要な工具:
MicrometerHistory & Context
History & Context
US 283,627, “Improvement in Gages”, John Logan of Waltham, Massachusetts, filed 15 May 1883, granted 21 August 1883.
A date correction. Several respectable secondary sources give this patent as 21 August 1886. The patent document itself is dated 1883, and the number is consistent with 1883 issues. Where a secondary source and the document disagree, the document wins.
What happened to it. Frank Randall, a watchmaker at the E. Howard Watch Company, bought Logan's patent rights in 1896 and went into partnership with Francis Stickney; Randall & Stickney of Waltham then manufactured dial indicators for general industry. The rack-and-pinion arrangement Logan developed is still the mechanism inside most mechanical dial indicators.
Why deviation matters more than size. On a production line nobody re-measures every dimension of every part. They set a master, zero an indicator against it, and then read only the difference for every part after. Reading a difference is faster, needs less skill, and is less error-prone than reading an absolute size — which is what let unskilled operators hold skilled tolerances. The gauge blocks and the comparator later in this batch are both built on the same insight.
材料
3- 6 枚プレースホルダー
- プレースホルダー
- プレースホルダー
接続ブループリントの材料
CC0 パブリックドメイン
このブループリントはCC0で公開されています。許可を求めずに、自由にコピー、修正、配布、あらゆる目的で使用できます。
メイカーを応援するには、ブループリント経由で製品を購入してください。メイカーには メイカーコミッション がベンダーにより設定されています。または、このブループリントの新しいイテレーションを作成し、自分のブループリントにコネクションとして含めて収益を共有できます。