SANAA
UREMBO NA USTAWI
UJANJA
UTAMADUNI NA HISTORIA
BURUDANI
MAZINGIRA
CHAKULA NA VINYWAJI
UHANDISI WA KINYUME
SAYANSI
MICHEZO
TEKNOLOJIA
VAZI
Counterflow: The Same Area Does More When the Streams Run Opposite
Youblob (generated from this blueprint's notebook) · CC0
Emma

Imeundwa na

Emma

27. Septemba 2026SE
5
0
0
0
0

Counterflow: The Same Area Does More When the Streams Run Opposite

Every heat exchanger in this batch — the economiser, the condenser, the plate exchanger — is built to one rule: make the hot and cold streams run in opposite directions. It is the single cheapest improvement in heat transfer, because it costs no extra metal. Run the same way, two streams approach a common middle temperature and stop; the cold one can never leave hotter than the hot one does. Run opposite, the cold stream meets the hottest fluid just as it leaves, and can come out warmer than the hot stream exits. This rung builds a tube-in-tube exchanger from a copper tube inside a hose, logs four temperatures with an Arduino, and runs it both ways to measure the difference.
Kati
About 5 hours

Maagizo

1

Parallel against counterflow, in numbers

Inapakia daftari la Jupyter…
2

Build a tube-in-tube exchanger

Take 2 m of 10 mm copper tube and slide it inside 2 m of clear vinyl tube with a bore comfortably larger — the annulus between them is the second channel. At each end fit a tee from the PVC fittings kit: the copper passes straight through the tee and is sealed where it exits with silicone; the tee's side branch is the jacket connection. You now have two independent channels: inside the copper, and between copper and vinyl. Coil the whole thing loosely and insulate it with glass wool, leaving the four connections free. Push a waterproof temperature probe into each of the four connections through a hole sealed with silicone.

Vifaa kwa hatua hii:

Mrija wa shaba mm 10Mrija wa shaba mm 102 mita
Mrija wa vinili angavuMrija wa vinili angavu2.5 mita
Mkusanyiko wa Viungio vya Bomba la PVCMkusanyiko wa Viungio vya Bomba la PVC1 seti
Kizibo cha SilikoniKizibo cha Silikoni1 kipande
Kizuizi cha joto cha sufu ya kiooKizuizi cha joto cha sufu ya kioo1 sqm
Mchanganyiko wa vibano vya mpiraMchanganyiko wa vibano vya mpira1 seti
Temperature Sensor - Waterproof (DS18B20)Temperature Sensor - Waterproof (DS18B20)4 vipande

Zana zinazohitajika:

Kikata bombaKikata bomba
Kekee cha BetriKekee cha Betri
Seti ya vichimbuziSeti ya vichimbuzi
Glavu za Kazi za NgoziGlavu za Kazi za Ngozi
3

The logger

Four DS18B20 probes on a single data wire, logging hot in, hot out, cold in and cold out every few seconds as comma-separated lines you can paste into the notebook or a spreadsheet.
hx_logger.inoarduino
/*
  hx_logger.ino -- log the four temperatures of a tube-in-tube heat exchanger.

  Four DS18B20 waterproof probes on ONE data wire: hot in, hot out, cold in,
  cold out. Libraries (Library Manager): "OneWire" and "DallasTemperature".
  Wiring: all probes' red -> 5V, black -> GND, yellow (data) -> D2.
          Pull-up between D2 and 5V of about 4.7 k: two 10 k resistors in
          parallel give 5 k, which works on short leads.
  First run prints each probe's address: label the probes in that order.
*/
#include <OneWire.h>
#include <DallasTemperature.h>

const int PIN_BUS = 2;
OneWire bus(PIN_BUS);
DallasTemperature sensors(&bus);
DeviceAddress addr[4];
const char* NAMES[4] = {"hot_in", "hot_out", "cold_in", "cold_out"};
int found = 0;

void printAddress(DeviceAddress a) {
  for (int i = 0; i < 8; i++) {
    if (a[i] < 16) Serial.print('0');
    Serial.print(a[i], HEX);
  }
}

void setup() {
  Serial.begin(9600);
  sensors.begin();
  found = sensors.getDeviceCount();
  if (found > 4) found = 4;
  for (int i = 0; i < found; i++) {
    sensors.getAddress(addr[i], i);
    sensors.setResolution(addr[i], 12);
    Serial.print(F("# probe ")); Serial.print(i); Serial.print(F(" = "));
    printAddress(addr[i]); Serial.print(F(" -> ")); Serial.println(NAMES[i]);
  }
  Serial.println(F("seconds,hot_in,hot_out,cold_in,cold_out"));
}

void loop() {
  sensors.requestTemperatures();          // ~750 ms at 12-bit resolution
  Serial.print(millis() / 1000);
  for (int i = 0; i < found; i++) {
    Serial.print(',');
    Serial.print(sensors.getTempC(addr[i]), 2);
  }
  Serial.println();
  delay(4000);
}

/*
  The heat each side carried, from the logged steady values:
     Q_hot  = m_hot  * 4186 * (hot_in  - hot_out)    watts, m in kg/s
     Q_cold = m_cold * 4186 * (cold_out - cold_in)
  They should agree within a few per cent. If Q_hot is much larger, heat is
  leaking out of the jacket to the room: insulate it.
*/

Vifaa kwa hatua hii:

Arduino Uno R3Arduino Uno R31 kipande
Kizuizi cha kilo-ohm 10Kizuizi cha kilo-ohm 102 vipande
Nyaya za KuunganishaNyaya za Kuunganisha1 seti

Zana zinazohitajika:

Kompyuta yenye IDE ya ArduinoKompyuta yenye IDE ya Arduino
4

Run it both ways

Feed the copper with hot water from a bucket on a shelf — about 60 °C from a kettle topped up with cold — and the jacket with cold tap water. Set both flows to the same rate by timing each outlet into a measuring jug (aim for about 1 litre per minute). **Parallel:** both streams enter at the same end. Let the logger settle for five minutes and note the four temperatures. **Counterflow:** swap the jacket's hoses so the cold enters at the far end. Keep both flows the same. Settle and note. Compare the cold outlet in the two runs. In counterflow it comes out noticeably warmer — often warmer than the hot outlet — with no change to the hardware except which way one hose points. Work out the heat each side carried; they should agree within a few per cent.

Vifaa kwa hatua hii:

MajiMaji40 lita

Zana zinazohitajika:

Birika la umeme la kiooBirika la umeme la kioo
NdooNdoo
Mtungi wa kupimiaMtungi wa kupimia
Saa ya kupima mudaSaa ya kupima muda
Kipima-joto cha jikoniKipima-joto cha jikoni
5

Context

A practice rung: no patent anchors counterflow — it is physics that engineers learned and wrote into every exchanger. The effectiveness–NTU method used in the notebook was set out in the mid-twentieth century and is how exchangers are sized today. Where it shows up in this catalogue: the economiser meets the coolest gas with the coldest water; the Stirling engine's regenerator and a rocket's regenerative cooling both depend on it; the Linde air liquefier works only because its counterflow exchanger lets the cold returning gas pre-cool the incoming gas. **Honest limits.** Counterflow gains most when you want the streams to approach each other's temperatures; for a small temperature change on one side it matters less. And it cannot beat the laws: with equal flows even a perfect counterflow exchanger only approaches 100 % effectiveness as its area goes to infinity.

Vifaa

11

Zana Zinazohitajika

10
Jumla inayokadiriwa
Kile mtengenezaji alinunua. Malighafi zisizo na bei hupatikana pale unaponunua.
$37.72

CC0 Umma Wote

Mchoro huu umetolewa chini ya CC0. Uko huru kunakili, kubadilisha, kusambaza, na kutumia kazi hii kwa madhumuni yoyote, bila kuomba ruhusa.

Saidia Mtengenezaji kwa kununua bidhaa kupitia Mchoro wao ambapo wanapata Kamisheni ya Mtengenezaji iliyowekwa na Wachuuzi, au unda marudio mapya ya Mchoro huu na uiunganishe kama kiungo katika Mchoro wako kuchangia mapato.

Majadiliano

(0)

Ingia kujiunga na majadiliano

Inapakia maoni...