Bonded Wire Strain Gauge on Paper: Simmons, 1942
Edward E. Simmons, Jr. of Pasadena patented the bonded wire strain gauge in 1942, US 2,292,549 (filed 1940). A very fine resistance wire is cemented to a member along its entire length, so it stretches and shortens exactly with the surface and its electrical resistance follows the strain. His preferred form: Constantan or Advance wire, about 0.003 inch, wound back and forth on a thin paper, set in Glyptal, then cemented to the member and calibrated.
උසස්
Workshop process
උපදෙස්
1
1
Wind the filament on thin paper
Wind the filament on thin paper
Use a fine resistance wire such as Constantan or Advance (a copper-nickel alloy, about 45 % nickel and 55 % copper); Simmons used No. 40 gauge, about 0.0031 inch. Wind it back and forth across a thin paper in parallel lengths whose alternate ends are joined, the strands very close together but not touching. A winding jig keeps the filament slightly taut.
මෙම පියවර සඳහා ද්රව්ය:
කොන්ස්ටන්ටන් කම්බි1 as required
කඩදාසි1 පත්රයඅවශ්ය මෙවලම්:
කම්බි එතීමේ ජිගය
කතුර2
2
Set it in Glyptal
Set it in Glyptal
Cover the wound filament with Glyptal and let it dry and harden thoroughly. Filament and paper now form one gauge unit, the filament lying in the plane of the paper surface.
මෙම පියවර සඳහා ද්රව්ය:
ග්ලිප්ටල් ඇල්කිඩ් දුම්මල1 as requiredඅවශ්ය මෙවලම්:
සියුම් බුරුසු
වේළන උදුන3
3
Cement it to the member
Cement it to the member
Put Glyptal on the surface of the member and wrap the gauge unit on with the strands running in the direction of the strain to be measured, the paper outside. The small amount of Glyptal on the surface insulates the filament from the member. Hold filament and paper in place by wrapping them with thread, then dry and harden the Glyptal thoroughly.
මෙම පියවර සඳහා ද්රව්ය:
ග්ලිප්ටල් ඇල්කිඩ් දුම්මල1 as required
කපු නූල්1 as requiredඅවශ්ය මෙවලම්:
සියුම් බුරුසු
වේළන උදුන
කතුර4
4
Calibrate it
Calibrate it
Load the member progressively in a materials testing machine and note the change in the filament's resistance at each load, measured on a Wheatstone bridge in which the filament is one arm. For very fast loads, as in impact tests, an oscillograph takes the place of the galvanometer.
අවශ්ය මෙවලම්:
ද්රව්ය පරීක්ෂණ යන්ත්රය
වීට්ස්ටෝන් සේතුව
ඇනලොග් ගැල්වනෝමීටරය5
5
Bonding area and signal size
Bonding area and signal size
Jupyter සටහන් පොත පූරණය වෙමින්…
ද්රව්ය
4- 1 as requiredස්ථානගත
- 1 පත්රයස්ථානගත
- 1 as requiredස්ථානගත
- 1 as requiredස්ථානගත
මෙම සැලසුම සාදන්නේ
සම්බන්ධ බ්ලූප්රින්ට්
මෙම බ්ලූප්රින්ට් දැනුම බෙදා ගනී — ශිල්ප ක්රම, ද්රව්ය හෝ මූලධර්ම
CC0 පොදු වසම
මෙම බ්ලූප්රින්ට් CC0 යටතේ නිකුත් කර ඇත. ඔබට අවසර නොමැතිව පිටපත් කිරීම, වෙනස් කිරීම, බෙදා හැරීම සහ භාවිතා කිරීම කළ හැක.
බ්ලූප්රින්ට් හරහා නිෂ්පාදන මිලදී ගැනීමෙන් නිර්මාතෘට සහාය වන්න නිර්මාතෘ කොමිසම විකුණුම්කරුවන් විසින් නියම කළ, හෝ මෙම බ්ලූප්රින්ට්හි නව අනුවාදයක් සාදා ආදායම බෙදා ගැනීමට ඔබේ බ්ලූප්රින්ට්හි සම්බන්ධතාවයක් ලෙස ඇතුළත් කරන්න.