Stripping Insulation Without Nicking the Copper

A nicked conductor is a wire that will break later. The cut is a stress concentration, the wire flexes there, and it fails weeks after you finished — inside the insulation, where nothing shows. On stranded wire the same mistake is quieter still: a few strands cut away and the wire carries less current than you think, runs warmer, and nothing looks wrong at all. Getting this right is almost entirely about using the correct hole on the stripper and not using a knife. It takes a minute to learn and it removes a whole class of intermittent fault.
Анхан шат
2 hours

Зааварчилгаа

1

Use the hole marked for the gauge you are cutting

A wire stripper has a row of holes, each sized for one gauge. Put the wire in the hole with its own number on it, squeeze, and the blades close to exactly the conductor's diameter — cutting the insulation and stopping at the copper. Using a hole one size too small cuts into the conductor. One size too large and the insulation tears instead of cutting, and you drag it off, stretching the wire behind it. Both are visible under a loupe and neither is visible to the naked eye. If the gauge is unmarked or unknown, start with a hole that is definitely too large and work down until the insulation parts cleanly. That costs three seconds and one scrap end.

Энэ алхмын материал:

Холбох утасХолбох утас1 ширхэг

Шаардлагатай багаж:

Утасны бүрээс хуулагчУтасны бүрээс хуулагч
Томруулагч лупТомруулагч луп
2

Never strip with a knife — and why the rotation trick still fails

A blade pressed hard enough to cut PVC is pressed hard enough to score copper, and the score is exactly where the wire will break. The common workaround — rolling the wire under the blade to cut all round — produces a ring of small nicks instead of one, and a ring of nicks is a perfect fracture line. It is worse than a single cut, not better. Where there is genuinely no stripper, the least bad method is to soften and pull: grip the insulation with pliers and draw it off, or for thick cable make a LENGTHWAYS slit well back from the end and fold the insulation open rather than cutting around the conductor. A lengthways cut does not create a break line.

Энэ алхмын материал:

Холбох утасХолбох утас1 ширхэг

Шаардлагатай багаж:

Нөөц иртэй урлалын хутгаНөөц иртэй урлалын хутга
Утасны бүрээс хуулагчУтасны бүрээс хуулагч
Томруулагч лупТомруулагч луп
3

Strip the right LENGTH, and check it against the joint

Too little and the conductor does not reach the bottom of the terminal; too much and bare copper stands proud of it, ready to touch its neighbour. The right length is set by the joint, not by habit. For a screw terminal, just enough that no bare wire shows outside the clamp. For a crimp, exactly the length of the barrel. For a solder joint on a pin, enough to wrap or sit against it and no more. Offer the stripped end up to the terminal before committing. A wire stripped too long can be trimmed; one stripped too short has to be cut back and redone, which shortens the wire every time and eventually costs you the whole run.

Энэ алхмын материал:

Холбох утасХолбох утас1 ширхэг

Шаардлагатай багаж:

Утасны бүрээс хуулагчУтасны бүрээс хуулагч
Шурагт холбогчийн блокШурагт холбогчийн блок
Бөгжин холбогч үзүүрБөгжин холбогч үзүүр
4

Twist stranded wire — but do not tin it for a screw terminal

Give stranded wire a light twist in the direction its strands already lie, just enough to keep them together. Heavy twisting distorts the bundle and makes it harder to seat. Do NOT tin a stranded wire that is going into a SCREW terminal. Solder creeps under sustained pressure — it flows slowly away from the clamped point — so the screw gradually loosens over months and the joint heats up. This is a real documented failure mode and it is forbidden in professional practice for exactly that reason. The correct answer for stranded wire into a screw terminal is a bootlace ferrule: a metal sleeve crimped onto the strands that presents a solid, non-creeping end to the screw. Tinning is fine where the joint is soldered anyway, and wrong wherever a screw is doing the clamping.

Энэ алхмын материал:

Утасны үзүүрийн бүрээсУтасны үзүүрийн бүрээс1 ширхэг
Холбох утасХолбох утас1 ширхэг

Шаардлагатай багаж:

Шахах хавчаарШахах хавчаар
Шурагт холбогчийн блокШурагт холбогчийн блок
Гагнуурын хэрэгсэлГагнуурын хэрэгсэл

Материал

2

Шаардлагатай багаж

7

Холбоотой загварууд

Эдгээр загварууд мэдлэг хуваалцдаг — арга техник, материал эсвэл зарчим

CC0 Нийтийн домэйн

Энэ загвар CC0 дор гаргагдсан. Та зөвшөөрөл авахгүйгээр хуулах, өөрчлөх, түгээх, ашиглах боломжтой.

Загвараар дамжуулан бүтээгдэхүүн худалдаж авч Бүтээгчийг дэмжээрэй Бүтээгчийн шимтгэл Борлуулагчаар тогтоосон, эсвэл энэ загварын шинэ хувилбар үүсгэж орлогоо хуваахын тулд өөрийн загварт холбоос болгон оруулна уу.

Хэлэлцүүлэг

(0)

Нэвтрэх хэлэлцүүлэгт нэгдэхийн тулд

Сэтгэгдлүүдийг ачаалж байна...