Bathroom Scale: Four Flat Load Cells Between Two Plates (Angel, 1991)
Penny

Nilikha ni

Penny

2. Nobyembre 2026DK
9
0
0
0
0

Bathroom Scale: Four Flat Load Cells Between Two Plates (Angel, 1991)

A floor scale only as thick as two plates. Four flat load cells sit in the corners between a base and a top plate; their strain gauges are wired into one bridge, so the signal is the sum of the four loads wherever you stand. Result: a low digital bathroom scale reading in pounds or kilograms. The patent gives under 0.05 % non-linearity, hysteresis and non-repeatability, and under 0.1 % error from off-centre loads; its feet let it stand on thick carpet. Source: S. Angel, US Patent 4,993,506 (1991). Unknown: the plate material and size, the maximum load, and the circuit. Ours: ebonite for the hard rubber, epoxy, the amplifier and display parts. Picture: patent drawing (Fig. 5).
Abantado
2 days

Mga Tagubilin

1

Mount the four load cells

Put one load cell in each corner of the rigid base plate. Screw each one down to small flat raised pads on the plate. Place the pads away from the edge of the cell's beam, so that fixing the cell does not change its sensitivity. Under each cell, tap two holes through the base for the overload screws. Not given: the plate material and size.

Mga materyales para sa hakbang na ito:

Load cellLoad cell4 piraso
Base at itaas na plato ng timbanganBase at itaas na plato ng timbangan1 base and top plate
Mga turnilyo ng makinaMga turnilyo ng makina8 cell screws

Mga kailangang kasangkapan:

Set sa paggawa ng sinulid ng turnilyoSet sa paggawa ng sinulid ng turnilyo
Set ng mga distornilyadorSet ng mga distornilyador
Hindi alam na sukatHindi alam na sukat
2

Wire one bridge and the readout

Each cell's two gauges are half a Wheatstone bridge. Join the four halves into one full bridge, one half at each corner, so the bridge gives a signal in step with the sum of the four loads. The signal is amplified, turned into numbers by an analog-to-digital converter, worked into pounds or kilograms and shown on a display. Put the electronics and batteries in the space between the plates. Not given: the circuit. Ours: an op-amp and a segment LCD.

Mga materyales para sa hakbang na ito:

IC na operasyonal na amplipikadorIC na operasyonal na amplipikador1 amplifier
Tagapalit ng Analog sa DigitalTagapalit ng Analog sa Digital1 piraso
Segment LCD panelSegment LCD panel1 piraso
BateryaBaterya1 as the circuit needs
Kawad na pandugtongKawad na pandugtong1 as needed
Kawad na PanghinangKawad na Panghinang1 a little

Mga kailangang kasangkapan:

PanghinangPanghinang
3

Fit the top plate on hard rubber pads

Glue four flat round pads of a rigid but slightly yielding material, such as hard rubber, under the top plate. Give each pad small round studs that snap into the two load holes of its cell, so the weight goes in at the centres of those holes. The pads soften impacts when something is dropped on the scale and take up sideways forces as the top plate bends. The snaps let the top plate be pulled off for repairs. Ours: ebonite and epoxy.

Mga materyales para sa hakbang na ito:

Baras na eboniteBaras na ebonite1 four pads
Epoksing dalawang bahagiEpoksing dalawang bahagi1 a little

Mga kailangang kasangkapan:

Lagaring Pang-metalLagaring Pang-metal
4

Fit the feet

Under the base, below each cell, fix a shallow foot of flexible material such as hard rubber, rounded underneath. Put its lowest point exactly below the centre of the cell's beam: the floor then pushes up at the beam's centre without bending it, and the scale works on thick carpet or uneven floors. Ours: ebonite.

Mga materyales para sa hakbang na ito:

Baras na eboniteBaras na ebonite1 four feet
Epoksing dalawang bahagiEpoksing dalawang bahagi1 a little

Mga kailangang kasangkapan:

Lagaring Pang-metalLagaring Pang-metal
5

Set the overload stops

Load the scale to its maximum capacity. Turn the short screws in from below until they just touch the arms of each cell's loading element, then lock them with adhesive. Any heavier load now rests on the screws instead of bending the cells further. Not given: the maximum capacity. Ours: calibration weights and epoxy.

Mga materyales para sa hakbang na ito:

Mga turnilyo ng makinaMga turnilyo ng makina8 overload screws
Epoksing dalawang bahagiEpoksing dalawang bahagi1 a little

Mga kailangang kasangkapan:

Set ng timbang na pangkalibrasyonSet ng timbang na pangkalibrasyon
Set ng mga distornilyadorSet ng mga distornilyador

Mga Materyales

11

Mga Kinakailangang Kasangkapan

6

Ang blueprint na ito ay gumagawa ng

Kaugnay na Blueprint

Ang mga blueprint na ito ay nagbabahagi ng kaalaman — mga teknik, materyales, o prinsipyo

CC0 Pampublikong Domain

Ang blueprint na ito ay inilabas sa ilalim ng CC0. Malaya kang kumopya, magbago, mamahagi, at gumamit nang walang pahintulot.

Suportahan ang Maker sa pamamagitan ng pagbili ng mga produkto sa kanilang Blueprint Komisyon ng Maker itinakda ng mga Vendor, o lumikha ng bagong bersyon ng Blueprint na ito at isama bilang koneksyon sa iyong Blueprint upang ibahagi ang kita.

Talakayan

(0)

Mag-login upang sumali sa talakayan

Naglo-load ng mga komento...