A short-stroke solenoid that opens an air valve. One coil pulls the iron armature down; a second, weaker coil holds it there against the air pressure once the first is switched off. A cast-iron shell closes the magnetic circuit around both. Result: an iron-clad plunger solenoid driving a brass valve rod through its hollow core. Source: C. P. Nachod's test (Electrical World, 1905) in Underhill, Solenoids, Electromagnets and Electromagnetic Windings (1910), pp. 125-129. Unknown: the wire insulation; the test does not give it. Not given: shell and armature sizes, voltage. Picture drawn by Youblob.
Hejuru
2 days

Amabwiriza

1

Turn the core and armature

Turn the core from Norway iron to 3.17 cm outside diameter and bore a 0.95 cm hole through it for the valve rod. Turn the armature from the same iron. Ours: wrought iron bar; the armature size is not given.

Ibikoresho by'iyi ntambwe:

Umugozi w'icyuma cyacuzweUmugozi w'icyuma cyacuzwe1 as required

Ibikoresho bikenewe:

Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)
2

Cast the shell and top

Cast the shell and top in cast iron so they close the magnetic circuit round the coils, leaving a round clearance gap for the armature in the top. Sizes: not given (Underhill's Fig. 92 shows the layout).

Ibikoresho by'iyi ntambwe:

Ibice by'icyuma kitatunganyijweIbice by'icyuma kitatunganyijwe1 as required

Ibikoresho bikenewe:

Itanura rihagazeItanura rihagaze
Agasanduku ko kubumbamoAgasanduku ko kubumbamo
Umucanga wo guteraUmucanga wo gutera
3

Wind coil A: 1860 turns of No. 25

Wind the operating coil, 1860 turns of No. 25 wire, and place it where it encircles the working air gap between armature and core. Copper, as Underhill gives for magnet windings. Unknown: the insulation; the test does not give it.

Ibikoresho by'iyi ntambwe:

Insinga y'UmuringaInsinga y'Umuringa1 as required
Ibikoresho bikumira amashanyarazi bitazwiIbikoresho bikumira amashanyarazi bitazwi1 as required

Ibikoresho bikenewe:

Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)
4

Wind coil B: 1765 turns of No. 26

Wind the retaining coil, 1765 turns of No. 26 wire, and place it below coil A on the core. Being away from the gap, it pulls only 0.4-0.8 as hard as A, enough to hold the armature down.

Ibikoresho by'iyi ntambwe:

Insinga y'UmuringaInsinga y'Umuringa1 as required

Ibikoresho bikenewe:

Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)
5

Assemble with the brass valve rod

Fit core, coils and armature in the shell and pass the brass rod through the core to the valve. Nachod set test gaps of 0.41 and 2.05 mm with brass washers.

Ibikoresho by'iyi ntambwe:

Umurongo w'Umuringa w'UmuhondoUmurongo w'Umuringa w'Umuhondo1 as required

Ibikoresho bikenewe:

Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)Icyegeranyo cy'ibikoresho by'imashini izunguruka (HSS)

Ibikoresho

5

Ibikoresho bikenewe

4

Iki gishushanyo gikora

Blueprint zijyanye

Izi blueprint zisangira ubumenyi — uburyo, ibikoresho cyangwa amahame

CC0 Umurenge rusange

Iyi blueprint yasohowe munsi ya CC0. Ushobora gukoporora, guhindura, gukwirakwiza no gukoresha nta kwemererwa.

Shyigikira Umuremyi ugura ibicuruzwa binyuze muri Blueprint ye Komisiyo y'Umuremyi byashyizweho n'Abacuruzi, cyangwa kora verisiyo nshya y'iyi Blueprint ukayinjiza nk'isano muri Blueprint yawe kugira ngo musangire inyungu.

Ibiganiro

(0)

Injira kugira ngo ujye mu biganiro

Gutegura ibitekerezo...