The Moving-Coil Meter: A Coil, a Spring and a Radial Field
Penny

Yaremwe na

Penny

27. Nzeli 2026DK
9
0
0
0
0

The Moving-Coil Meter: A Coil, a Spring and a Radial Field

A needle that swings across a scale in proportion to the current: the moving-coil meter was the standard electrical instrument for a century. Edward Weston's patents of 1888 made it portable and accurate. A light coil of fine wire on jewelled pivots sits between the poles of a permanent magnet, around a fixed iron cylinder; hair springs hold it at zero and carry the current in; the coil is wound on a copper frame that damps its swing so the needle settles instead of oscillating. The iron cylinder is the clever part. It makes the magnetic field in the gap radial, so the coil's torque does not change as it turns, and the scale comes out evenly spaced. This rung shows why in a notebook, then builds a thread-suspended galvanometer and demonstrates the damping.
Hagati
About 5 hours

Amabwiriza

1

Read Weston's patent

US 392,386 and US 392,387, 'Electrical Measuring Apparatus', Edward Weston, dated 6 November 1888 (the second a division of an application filed 17 March 1888). The current circulates *"through a coil or loop in the circuit, which coil is supported so as to be free"* to turn against *"a uniform resilient resistance"*, so that its movement *"shall be directly proportional"* to the current. The coil *"incloses a frame … of copper"*, and the patent explains that combining a *"diamagnetic mass with the said coil"* prevents *"undue oscillation"* — eddy-current damping.
2

Why the scale is linear

Gupakira ikaye ya Jupyter…
3

Build a thread-suspended galvanometer

Print a rectangular coil former 20 × 20 mm and wind 50 turns of enamelled copper wire on it. Hang it by a single cotton thread from a bracket, so it can twist freely; bring the two wire ends down as fine, loose flexible leads. Glue a drinking-straw pointer to the top and a paper protractor scale behind it. Place two neodymium magnets either side of the coil, one north-facing, one south-facing. Connect a 1.5 V cell through a resistor from the resistor kit (a few hundred ohms) and the multimeter in series. The coil turns until the thread's twist balances it. Try four resistors: deflection against current should be close to a straight line while the angle is small.

Ibikoresho by'iyi ntambwe:

Insinga y'Umuringa Yasizwe EnameliInsinga y'Umuringa Yasizwe Enameli1 umuzingo
Fibere ya PETGFibere ya PETG10 g
Ubudodo bw'IpambaUbudodo bw'Ipamba1 umuzingo
Umutwe w'ibyuma bikurura bya neodimiyumuUmutwe w'ibyuma bikurura bya neodimiyumu1 ikirundo
Ikusanyirizo ry'Ibirwanya AmashanyaraziIkusanyirizo ry'Ibirwanya Amashanyarazi1 ikirundo
Insinga z'Ibizamini Zifite IbifatanyoInsinga z'Ibizamini Zifite Ibifatanyo1 ikirundo

Ibikoresho bikenewe:

Imashini icapa 3D ikoresha umugozi (FDM)Imashini icapa 3D ikoresha umugozi (FDM)
Igipimo cy'amashanyarazi kinyuranyeIgipimo cy'amashanyarazi kinyuranye
Igipima IngoroIgipima Ingoro
4

Damp it by shorting the coil

Disconnect the cell and give the coil a small twist by hand. It swings back and forth many times before settling. Now join the two coil leads together with a clip and twist it again. It settles almost at once. Moving through the field, the coil generates a current in its own shorted circuit, and that current's force opposes the motion — the same effect Weston got from the copper frame, and the same one the eddy-current brake in this catalogue uses.

Ibikoresho bikenewe:

Insinga z'Ibizamini Zifite IbifatanyoInsinga z'Ibizamini Zifite Ibifatanyo
5

History and context

**US 392,386 and US 392,387, 'Electrical Measuring Apparatus', Edward Weston, dated 6 November 1888.** Arsène d'Arsonval had built a moving-coil galvanometer with a suspended coil in 1882; Weston made it robust and portable with pivots, springs, a permanent magnet and the radial field. Weston's company made the instruments that measured the electrical industry for decades. **Honest limits.** A moving-coil movement responds only to direct current — on AC it needs a rectifier. It draws current from the circuit it measures (the next rung). Pivots wear, springs age, and a strong knock or overload bends the needle.

Ibikoresho

6

Ibikoresho bikenewe

4

CC0 Umurenge rusange

Iyi blueprint yasohowe munsi ya CC0. Ushobora gukoporora, guhindura, gukwirakwiza no gukoresha nta kwemererwa.

Shyigikira Umuremyi ugura ibicuruzwa binyuze muri Blueprint ye Komisiyo y'Umuremyi byashyizweho n'Abacuruzi, cyangwa kora verisiyo nshya y'iyi Blueprint ukayinjiza nk'isano muri Blueprint yawe kugira ngo musangire inyungu.

Ibiganiro

(0)

Injira kugira ngo ujye mu biganiro

Gutegura ibitekerezo...