The Plate Heat Exchanger: Thin Plates, Turbulence, and a Frame You Can Open
A stack of thin pressed-metal plates, each sealed to the next by a gasket round its edge, clamped between two heavy frame plates by long bolts. Hot and cold liquids flow in alternate gaps, so every plate has hot on one face and cold on the other.
Richard Seligman's plate heat exchanger of 1923, made by his Aluminium Plate & Vessel Company (APV), was built for the dairy: milk had to be heated and cooled quickly for pasteurisation, and the equipment had to come apart for cleaning every day. Thin corrugated plates give very high heat transfer in a small space; the gasketed frame opens with a spanner.
This rung works out where the size advantage comes from, and builds a two-channel plate exchanger from copper sheet, printed gaskets and a clamped frame.
Hagati
About 6 hours
Amabwiriza
1
1
Where the high U comes from, and what fouling costs
Where the high U comes from, and what fouling costs
Gupakira ikaye ya Jupyter…
2
2
Plate exchangers run in counterflow
Plate exchangers run in counterflow
A plate exchanger's ports are arranged so the two liquids run in opposite directions through alternate gaps. The embedded blueprint explains why, and measures it on a tube-in-tube exchanger.
3
3
Build a two-channel plate exchanger
Build a two-channel plate exchanger
Cut three copper sheets 150 × 100 mm. The middle one is the heat-transfer plate; the outer two are blanks. Print two gasket frames in TPU, 3 mm thick, each the outline of the plate with a 10 mm border, so each frame encloses a flow gap.
Stack: acrylic end plate / copper blank / gasket frame / copper plate / gasket frame / copper blank / acrylic end plate. Drill four corner bolt holes through everything and clamp with threaded rod and wing nuts, tightening evenly.
Drill and fit hose tails so that gap 1 is fed at the top-left and drains at the bottom-right, and gap 2 is fed at the bottom-right and drains at the top-left — counterflow across the plate. Add ridges to the gasket frames or press shallow chevrons into the copper with a blunt punch to break up the flow.
Ibikoresho by'iyi ntambwe:
Urupapuro rw'Umuringa1 urupapuro
Umugozi Woroshye wa TPU40 g
Urupapuro rwa Akiriliki1 urupapuro
Inkoni ifite imirongo1 igice
Inoti y'amababa4 ibice
Urutonde rw'ibihuza umuyoboro wa PVC1 ikirundoIbikoresho bikenewe:
Imashini icapa 3D ikoresha umugozi (FDM)
Icyuma Cyivumbura Kidafite Insinga
Ibyuma Byinshi byo Gucukura
Umurongo w'ipima
Isupana ihindurwa
Uturindantoki tw'uruhu tw'akazi4
4
Test it, then open it
Test it, then open it
Run hot water through one gap and cold through the other at equal, timed flows, and read the four temperatures with the thermometer (or reuse the four-probe logger from the counterflow rung). Work out the heat carried by each side.
Now the reason the design exists: undo the wing nuts, lift the stack apart and look. Any sediment, scale or film is on the copper where you can wipe it. Wipe, restack and tighten. An exchanger you can open is an exchanger you can keep clean — which in a dairy is the difference between a safe product and a spoiled one.
Retighten evenly: a gasket squeezed harder on one side leaks on the other.
Ibikoresho by'iyi ntambwe:
Amazi30 litiroIbikoresho bikenewe:
Ibirika by'amashanyarazi by'ikirahure
Indobo
Icyombo cyo gupima
Isaha yo Guhagarika
Igipimo cy'ubushyuhe cy'igikoni
Isupana ihindurwa5
5
History and context
History and context
**Richard Seligman, 1923** — the first commercially successful plate heat exchanger, made by the Aluminium Plate & Vessel Company he had founded in London in 1910, for the high-temperature short-time pasteurisation of milk. No patent number is asserted here: it could not be read from a primary source, and the design is fully documented.
Plate exchangers now run in food, brewing, district heating, heat pumps and chemical plant; brazed versions with no gaskets at all are the small cube in many domestic boilers.
**Honest limits.** Gaskets limit the temperature and pressure, and the chemicals they can meet. Narrow gaps clog on fibrous or particle-laden liquids, where shell-and-tube exchangers still win. And the high pressure drop of those turbulent gaps costs pumping power.
Ibikoresho
8- 1 urupapuroUmwanya
- Umwanya
- 1 urupapuroUmwanya
- 1 igiceUmwanya
- 4 ibiceUmwanya
- 1 ikirundoUmwanya
- 1 igiceUmwanya
- 30 litiroUmwanya
Ibikoresho bikenewe
11- 1 vendor sell this, none ship to you yetUmwanya
- Umwanya
- Umwanya
- Umwanya
- Umwanya
- Umwanya
- Umwanya
Blueprint zijyanye
Izi blueprint zisangira ubumenyi — uburyo, ibikoresho cyangwa amahame

Counterflow: The Same Area Does More When the Streams Run Opposite
na Emma
Mekanike
36
0
0
0
0
0

The Economiser: The Heat Still Going Up the Chimney
na Martin
Mekanike
38
0
0
0
0
0

The Centrifugal Pump: Speed Squared, and Why It Cannot Lift Air
na Emma
Mekanike
34
0
0
0
0
0

The Ferrule Fitting: Gripping and Sealing With One Nut
na Emma
Ibikoresho
41
0
0
0
0
0
CC0 Umurenge rusange
Iyi blueprint yasohowe munsi ya CC0. Ushobora gukoporora, guhindura, gukwirakwiza no gukoresha nta kwemererwa.
Shyigikira Umuremyi ugura ibicuruzwa binyuze muri Blueprint ye Komisiyo y'Umuremyi byashyizweho n'Abacuruzi, cyangwa kora verisiyo nshya y'iyi Blueprint ukayinjiza nk'isano muri Blueprint yawe kugira ngo musangire inyungu.