Bouwers Rotating-Anode X-Ray Tube
Tehlikeli
Emma

Oluşturan

Emma

8. Eylül 2026SE
0
0
0
0
0

Bouwers Rotating-Anode X-Ray Tube

Coolidge's tube of 1913 solved the electrical problem: a heated filament sets the current, so the operator finally controls the beam instead of negotiating with a bag of gas. What it handed over was a **thermal** problem, and a brutal one. Only about one per cent of the power you put into an X-ray tube leaves as X-rays. The rest becomes heat, delivered into a focal spot a couple of millimetres across. At 100 kV and 400 mA that is roughly 40 kilowatts arriving in an area smaller than a grain of rice - hundreds of times the power density of a hotplate, into tungsten. The spot does not gradually warm. It pits, and then it melts, and a pitted anode makes a blurred and asymmetric beam for the rest of the tube's life. Albert Bouwers' answer at Philips was to stop letting the beam hit the same place twice. **US 1,933,005** "X-ray tube", filed 13. March 1930 and granted 31. October 1933: put the target on a disc and spin it, so the beam traces a ring of fresh metal instead of a point. The patent says why plainly - "since the bombarded surface of the anticathode is materially larger than in tubes of the type having a concentrated focal spot which is formed on a stationary anticathode, such tubes present the advantage that a much higher load may be applied". It sold as the Rotalix from 1929. **The clever part is how it is driven.** You cannot run a shaft through the wall of a vacuum tube and still have a vacuum. So the anode is mounted on a rotor sealed INSIDE the envelope, and the patent claims "a metallic stator carrying magnetic coils for imparting rotative motion to said anode and arranged without the tube" - an induction motor whose stator is outside the glass and whose rotor is inside it, coupled by nothing but a magnetic field. Nothing passes through the wall at all. **That is what you will build.** Not an X-ray tube - this blueprint asks nobody to make ionising radiation - but the actual mechanism Bouwers patented: a stator outside a sealed glass jar spinning a rotor inside it, with no connection between them. It is the same motor, at the same working principle, and you will measure its speed, its slip and its run-up time.
Orta
3 hours

Tehlikeli içerik

Bu blueprint tehlikeli prosedürler içermektedir. Adım adım talimatları görmek için giriş yapın ve hesap ayarlarınızda tehlikeli içeriği etkinleştirin.

CC0 Kamu Malı

Bu plan CC0 lisansıyla yayınlanmıştır. İzin almadan kopyalayabilir, değiştirebilir, dağıtabilir ve herhangi bir amaçla kullanabilirsiniz.

Planı üzerinden ürün satın alarak Maker'ı destekleyin, böylece Maker Komisyonu Satıcılar tarafından belirlenen komisyonu kazanırlar veya bu Planın yeni bir versiyonunu oluşturun ve gelir paylaşımı için kendi Planınıza bağlantı olarak ekleyin.