Fractionating Still: Hempel Bead Column on a Round Flask with Liebig Condenser (Gattermann, 1901)
Charlie

Створено

Charlie

3. листопад 2026DE
11
0
0
0
0

Fractionating Still: Hempel Bead Column on a Round Flask with Liebig Condenser (Gattermann, 1901)

The classic laboratory set-up for splitting a mixture of liquids by boiling point. A round flask is topped by a Hempel column, a tube packed with glass beads, with a side outlet near the top and a thermometer in a cork above it. The higher-boiling vapour condenses on the beads and runs back, so the vapour reaching the outlet is richer in the lower-boiling part; a Liebig condenser turns it to liquid in the receiver. One pass through it separates better than repeated distillations from a plain flask. Result: a fractionating still for laboratory distillations at atmospheric pressure. Source: L. Gattermann, The Practical Methods of Organic Chemistry (2nd American ed., 1901), pp. 16-24. Unknown: column and bead sizes. Picture: the book's Figs. 14-15.
Середній
Unknown

Інструкції

1

Make the Hempel column

Take a wide glass tube with a side outlet tube near its top and fill it with glass beads; the beads act like sieves, holding back the higher-boiling part. Fit it to a round, short-necked flask with a bored cork (or have it fused onto the bulb); flasks with the same neck width can share one cork. Choose a flask the charge will fill about two-thirds. Not given: sizes. Ours: a glass tube for the column body.

Матеріали для цього кроку:

Скляна трубкаСкляна трубка1 column
Скляний бісерСкляний бісер1 packing
Круглодонна колбаКруглодонна колба1 штука
КоркиКорки2 штук

Необхідні інструменти ({count})

Свердло для корківСвердло для корків
2

Set the thermometer and condenser

Pass the thermometer through a cork (not rubber) in the top of the column so its bulb sits level with the outlet, never down in the liquid. For liquids boiling up to 100° join the outlet to a Liebig condenser with a cork (long for very low boilers, short for high); from 100-200° cool the receiver with running water; above that a wide glass tube 50 cm long on the outlet is enough. If the vapour attacks cork, push the outlet far into the condenser instead. Clamp the apparatus above the outlet, never below it, or the hot glass may crack.

Матеріали для цього кроку:

Лабораторний термометрЛабораторний термометр1 штука
Водяний холодильникВодяний холодильник1 штука
Колба ЕрленмаєраКолба Ерленмаєра2 receivers

Необхідні інструменти ({count})

Штатив лабораторнийШтатив лабораторний
Свердло для корківСвердло для корків
3

Fractionate

Add a few bits of glass or platinum wire against bumping. Heat on the water-bath for liquids boiling up to about 80°, otherwise over a small free flame moved slowly to and fro under the flask, never above the liquid level, so the distillate falls into the receiver steadily in drops. With the Hempel column stop heating now and then so the liquid held in the beads can run back. Collect the first runnings, the main fraction at a steady temperature, and the last runnings in separate receivers; for a mixture, collect fractions over set ranges and distil them again.

Необхідні інструменти ({count})

Пальник БунзенаПальник Бунзена
Штатив лабораторнийШтатив лабораторний

Матеріали

7

Необхідні інструменти

3

За цим кресленням виготовляють

Пов'язані креслення

Ці креслення діляться знаннями — техніки, матеріали або принципи

CC0 Суспільне надбання

Це креслення випущено під ліцензією CC0. Ви можете вільно копіювати, змінювати, поширювати та використовувати цю роботу для будь-яких цілей без запиту дозволу.

Підтримайте мейкера, купуючи продукти через його креслення, де він отримує Комісію мейкера встановлену вендорами, або створіть нову ітерацію цього креслення та включіть його як зв'язок у власне креслення для розподілу доходу.

Обговорення

(0)

Увійти щоб приєднатися до обговорення

Завантаження коментарів...