ART
BEAUTY & WELLNESS
CRAFT
CULTURE & HISTORY
ENTERTAINMENT
ENVIRONMENT
FOOD & DRINKS
REVERSE ENGINEERING
SCIENCES
SPORTS
TECHNOLOGY
WEARABLES
Liquid Hydrogen: Gas at 200 Atmospheres Cooled by Dry Ice and Liquid Air, then Expanded in a Regenerator Coil (Travers, 1901)
Charlie

Created by

Charlie

1. November 2026DE
0
0
0
0
0

Liquid Hydrogen: Gas at 200 Atmospheres Cooled by Dry Ice and Liquid Air, then Expanded in a Regenerator Coil (Travers, 1901)

Hydrogen will not cool when it expands at room temperature, so Travers first chilled it with dry ice and then with liquid air boiling under a vacuum. Only then did expansion through a fine valve inside a regenerator coil cool it further, until clear liquid hydrogen ran into a vacuum vessel. Result: liquid hydrogen (specific gravity 0.06), cold enough to freeze air solid. Source: M. W. Travers, The Experimental Study of Gases (1901), pp. 196-206. Hydrogen is flammable; liquid air and liquid hydrogen are extremely cold. Picture: Fig. 103 of the book.
Advanced
1 week

Instructions

1

Make and store the hydrogen

Put about 40 lb of commercial granulated zinc in a beer cask with a tap funnel, a delivery tube, an escape pipe into a vessel of water (safety valve) and a stoneware cock at the bottom to draw off spent acid. Run in dilute sulphuric acid. When the air is out, pass the gas through a wash-bottle of potassium permanganate into the gasometer (sheet iron, 6 ft high, 5 ft 6 in across, over water first saturated with hydrogen). Wash the gasometer out with hydrogen before collecting the main quantity. This takes five hours.

Materials for this step:

HydrogenHydrogen1 a gasometer full, made here

Tools needed:

ZincZinc
Dilute Sulfuric AcidDilute Sulfuric Acid
Wooden BarrelWooden Barrel
Dropping FunnelDropping Funnel
Potassium PermanganatePotassium Permanganate
Gas Washing BottleGas Washing Bottle
GasholderGasholder
WaterWater
2

Make liquid air and ready the compressor

In the two or three days before, use the compressor to make liquid air with the Hampson liquefier and store it in vacuum vessels, about 8 litres in all. Then take the compressor apart and check the valves, springs and fibre packings. Remove the Hampson machine and connect the compressor through the cylinder of caustic potash to the hydrogen liquefier.

Tools needed:

Gas CompressorGas Compressor
Hampson Air LiquefierHampson Air Liquefier
Liquid AirLiquid Air
Vacuum Vessel (Dewar)Vacuum Vessel (Dewar)
3

Cool the liquefier

Four people are needed. Pack the vessel round coil A with solid carbonic acid and alcohol (-80 °C). Pour liquid air into chamber B and let it into chamber C, pumped down to 100 mm of mercury so it boils below -200 °C. Draw liquid air into vacuum vessel H and boil it under reduced pressure to chill the regenerator coil below -200 °C, then let it out and put vessels K and M (with a little liquid air) back in place.

Tools needed:

Hydrogen LiquefierHydrogen Liquefier
Solid Carbon DioxideSolid Carbon Dioxide
Ethanol - Denatured, 95%Ethanol - Denatured, 95%
Liquid AirLiquid Air
Vacuum Vessel (Dewar)Vacuum Vessel (Dewar)
Vacuum PumpVacuum Pump
Vacuum GaugeVacuum Gauge
4

Compress the hydrogen to 200 atmospheres

Purge the air from the compressor: open cock a, run a few turns, stop and open cock rho; do this three or four times. Then raise the pressure. The first cylinder takes the gas to about 16 atm, with a little glycerol and water holding 5 % caustic soda as lubricant; the second takes it to about 200 atm. The water is separated out and the gas dried over lumps of solid caustic potash. Have it at 200 atm by the time the liquefier is cold.

Tools needed:

Gas CompressorGas Compressor
GlycerinGlycerin
Lye (Sodium Hydroxide)Lye (Sodium Hydroxide)
WaterWater
Potassium HydroxidePotassium Hydroxide
Pressure GaugePressure Gauge
5

Expand and collect the liquid

Reconnect chamber C to the exhaust pump and let liquid air in slowly (a fall of the mercury in the vacuum gauge means too fast). Open the expansion valve with the milled nut; let the gas out through the water tank for a few moments to clear the air, then open cock i so it circulates back. Keep B and the coil-A vessel topped up. Watch the glycerol gauge for the flow and turn the milled nut slowly back and forth the whole time so it does not block. H coats with white solid air; open cock r now and then, and the liquid runs through a baize filter into K. Lift K out on its wire into a vessel with a little liquid air. About 10 % of the gas is lost per run.

Tools needed:

Hydrogen LiquefierHydrogen Liquefier
Liquid AirLiquid Air
Solid Carbon DioxideSolid Carbon Dioxide
Vacuum Vessel (Dewar)Vacuum Vessel (Dewar)
Vacuum PumpVacuum Pump
Vacuum GaugeVacuum Gauge
Pressure GaugePressure Gauge

Materials

1
  • 1 a gasometer full, made here
    Placeholder

Tools Required

21

CC0 Public Domain

This blueprint is released under CC0. You are free to copy, modify, distribute, and use this work for any purpose, without asking permission.

Support the Maker by purchasing products through their Blueprint where they earn a Maker Commission set by Vendors, or create a new iteration of this Blueprint and include it as a connection in your own Blueprint to share revenue.

Discussion

(0)

Log in to join the discussion

Loading comments...