Pressure Reactor: the Cast-Iron Autoclave with Bolted Cover (Thorpe, 1912)
Forge

Created by

Forge

4. November 2026NO
1
0
0
0
0

Pressure Reactor: the Cast-Iron Autoclave with Bolted Cover (Thorpe, 1912)

The chemical works' autoclave, built on Papin's digester: a closed cast-iron vessel with a flanged cover bolted down on a lead washer, a pressure gauge, a safety valve and a thermometer tube. It heats liquids above their boiling points, often at 20 to 30 atmospheres, in a bath of hot oil or molten lead. Variable: the material (cast iron, steel, copper, sheet iron) and lining (enamel, tin, lead, copper or zinc). Source: Thorpe, Dictionary of Applied Chemistry, vol. I (1912), pp. 343-344. Unknown: sizes, wall thickness. Picture: Fig. 3 of the book.
Expert
Unknown

Instructions

1

Cast the body and cover

Make the vessel of cast iron (or steel; occasionally copper, sheet iron or sheet steel), with a flange for the cover (Figs. 1-3). Cast-iron vessels are sometimes strapped with steel rings for safety. Not given: sizes and wall thickness.

Materials for this step:

Iron CastingsIron Castings2 body, cover
Mild Steel Flat BarMild Steel Flat Bar1 rings, optional

Tools needed:

Unknown DimensionsUnknown Dimensions
2

Fit gauge, valve and thermometer tube

Fit a pressure gauge, a safety valve and tubes for thermometers. If the charge would attack the iron, enamel the inside or line it with sheet tin, lead, copper or zinc soldered tight to the wall.

Materials for this step:

Pressure GaugePressure Gauge1 piece
Unknown ValveUnknown Valve1 safety valve
Iron TubeIron Tube1 thermometer tube

Tools needed:

Spanner SetSpanner Set
3

Close the cover

Close it with a screwed or flanged cover bearing on a lead washer, bolted down evenly.

Materials for this step:

Lead SheetLead Sheet1 washer
Hex Bolt - Grade 8.8Hex Bolt - Grade 8.81 flange bolts, number not given

Tools needed:

Spanner SetSpanner Set
4

Pressure-test and heat

Because it must hold 20 to 30 atmospheres, test it with hydraulic (water) pressure before use. In service, heat it by circulating hot oil or by standing it in a bath of molten lead.

Tools needed:

Hand Pressure Test PumpHand Pressure Test Pump
WaterWater
Molten Lead BathMolten Lead Bath

Materials

7

Tools Required

5

CC0 Public Domain

This blueprint is released under CC0. You are free to copy, modify, distribute, and use this work for any purpose, without asking permission.

Support the Maker by purchasing products through their Blueprint where they earn a Maker Commission set by Vendors, or create a new iteration of this Blueprint and include it as a connection in your own Blueprint to share revenue.