Making Up a Solution: Which Glassware Actually Measures, and Which Only Looks Like It

The graduations printed on a beaker are decoration. They are there so you can see roughly how full it is, and they are commonly 5% out — which is a hundred times worse than the flask standing next to it. Glassware divides into two families and the difference is enormous. VOLUMETRIC glassware — volumetric flasks, bulb pipettes, burettes — is made and tested to deliver one stated volume accurately. Everything else is a container with marks on it. Which you reach for is a decision about what the solution is FOR. Rinsing something out needs a beaker; a solution whose concentration will appear in a result needs a volumetric flask, and using the wrong one quietly poisons every number downstream.
Oqalayo
2 hours

Imiyalelo

1

Weigh the solid, and dissolve it somewhere else first

Weigh the solid on a precision balance, into a weighing container rather than onto the pan, and write the ACTUAL mass down — not the mass you intended. The difference between 5.00 g and 5.03 g is the difference between a calculated concentration and a guessed one. Dissolve it in a BEAKER with a smaller volume of solvent than the final target, not in the volumetric flask. Solids dissolve slowly, need stirring, and sometimes need warming, and a volumetric flask has a narrow neck that makes all three awkward. Make sure it is completely dissolved before going any further. Undissolved solid transferred into the flask is solid that is not in your solution, and the concentration you calculate will be higher than the one you have.

Izinto zokwakha zalesi sinyathelo:

I-sodium chloride (usawoti)I-sodium chloride (usawoti)1 ucezu
Amanzi AcwengisisiweAmanzi Acwengisisiwe1 ilitha

Amathuluzi adingekayo:

Isikali EsinembileIsikali Esinembile
Ibhikha LengilaziIbhikha Lengilazi
IsipatulaIsipatula
Induku YokugovuzaInduku Yokugovuza
2

Transfer, rinse, and rinse again

Pour the dissolved solution into the volumetric flask through a funnel, then rinse the beaker with a little solvent and pour that in too. Then do it again. Rinse the stirring rod and the funnel into the flask as well. Whatever stays behind in the beaker is solute missing from your solution. A beaker that looks empty holds a film worth a percent or more of a small quantity, and three small rinses recover nearly all of it. A wash bottle makes this easy and precise: a thin jet reaches the walls and the rod without adding much volume. The rinsings go into the flask, never into the sink — they are part of the measurement.

Izinto zokwakha zalesi sinyathelo:

Amanzi AcwengisisiweAmanzi Acwengisisiwe1 ilitha

Amathuluzi adingekayo:

Ibhodlela levolumuIbhodlela levolumu
Ifanela Lengilazi ElinomlomoIfanela Lengilazi Elinomlomo
Ibhodlela lokuhlanzaIbhodlela lokuhlanza
Ibhikha LengilaziIbhikha Lengilazi
3

Make up to the mark — and what the mark means

Ilayisha incwadi ye-Jupyter…

Izinto zokwakha zalesi sinyathelo:

Amanzi AcwengisisiweAmanzi Acwengisisiwe1 ilitha

Amathuluzi adingekayo:

Ibhodlela levolumuIbhodlela levolumu
Isilinda sokukalaIsilinda sokukala
Isikali EsinembileIsikali Esinembile
Ikhompyutha YasetafuleniIkhompyutha Yasetafuleni
4

Invert to mix, then label

Stopper the flask and invert it completely, twenty times or so, letting the bubble travel the full length each time. Swirling does not mix a volumetric flask: the dense solution sits in the bulb and the neck stays nearly pure solvent. This matters more than it sounds. An unmixed flask sampled from the neck gives a concentration far below the real one, and it is a mistake that produces beautifully reproducible wrong answers — the systematic error the measurement batch warns about. Then label it: substance, concentration, solvent, date, initials. And do not STORE solutions in volumetric flasks; transfer to a proper bottle. A volumetric flask is a measuring instrument, and leaving solution to dry in the neck around the graduation is how one stops being accurate.

Izinto zokwakha zalesi sinyathelo:

Amalebula AnamathelayoAmalebula Anamathelayo1 ucezu

Amathuluzi adingekayo:

Ibhodlela levolumuIbhodlela levolumu
Ipeni ElingesulekiyoIpeni Elingesulekiyo
Ibhuku LokubhalaIbhuku Lokubhala

Izinto

3

Amathuluzi Adingekayo

11

CC0 Isizinda Somphakathi

Le blueprint ikhishwe ngaphansi kwe-CC0. Ukhululekile ukukopisha, ukuguqula, ukusabalalisa, nokusebenzisa ngaphandle kwemvume.

Sekela uMenzi ngokuthenga imikhiqizo nge-Blueprint yabo IKhomishane Yomenzi kumiswe ngabathengisi, noma dala inguqulo entsha yale Blueprint bese uyifaka njengoxhumaniso ku-Blueprint yakho ukuze wabelane ngemali engenayo.

Ingxoxo

(0)

Ngena ukuze ujoyine ingxoxo

Kulayishwa amazwana...