USB-B Cable: Type-A Plug to Type-B Plug, Wired to the USB 2.0 Specification

A USB-B cable joins a computer (Type-A plug) to a device such as an Arduino board or a printer (Type-B plug). The USB 2.0 Specification (USB Implementers Forum, 2000) fixes the wiring: contact 1 VBUS on the red wire, 2 D- white, 3 D+ green, 4 GND black, and the plug shells joined through the cable's shield. It also sets the cable's build and its limits: a twisted green-white data pair, a red-black power pair, foil and braid shields, no more than 26 ns of delay, and less than 0.6 ohm from shell to shell. This rung works out how long the cable may be, then cuts a 1.5 m shielded cable, solders a Type-A plug to one end and a Type-B plug to the other, and checks every wire with a multimeter. Source: Universal Serial Bus Specification Rev. 2.0, sections 6.4.1, 6.5.2, 6.6, 7.1.16, 7.2.2. Picture: our own drawing.
Ophakathi
About 1 hour

Imiyalelo

1

How long may it be?

The delay and voltage-drop limits from the specification, and what they allow for each wire size.
2

Cut and strip the cable

Cut 1.5 m of shielded USB cable with a 24 AWG power pair. At each end, slit and remove 20 mm of the PVC jacket with the knife. Comb the braid back over the jacket, trim the foil off and keep the bare drain wire. Strip 3 mm of insulation from the red, black, green and white wires.

Izinto zokwakha zalesi sinyathelo:

Ikhebula le-USB elivikelweIkhebula le-USB elivikelwe1.5 m

Amathuluzi adingekayo:

Ithephu LokulinganisaIthephu Lokulinganisa
Ummese wemisebenziUmmese wemisebenzi
Isisiki sezintamboIsisiki sezintambo
Isihlubuli sikawayaIsihlubuli sikawaya
Izibuko zokuphephaIzibuko zokuphepha
3

Solder the Type-A plug

Slide the plug's hood and a 40 mm piece of heat-shrink tubing onto the cable. Tin the wires and solder them to the plug's contacts: 1 red (VBUS), 2 white (D-), 3 green (D+), 4 black (GND). Twist the drain wire into the braid and solder both to the plug's metal shell.

Izinto zokwakha zalesi sinyathelo:

Ipulaki ye-USB yohlobo AIpulaki ye-USB yohlobo A1 ucezu
Ishubhu elifinyelayo ngokushisaIshubhu elifinyelayo ngokushisa40 mm
Ucingo LwesodaUcingo Lwesoda1 as required

Amathuluzi adingekayo:

Insimbi yokushiselaInsimbi yokushisela
Izandla ezisizayoIzandla ezisizayo
4

Solder the Type-B plug

Do the same at the other end with the Type-B plug: 1 red (VBUS), 2 white (D-), 3 green (D+), 4 black (GND), drain wire and braid to the shell. Pin 1 must reach pin 1 at both ends.

Izinto zokwakha zalesi sinyathelo:

Ipulaki ye-USB yohlobo BIpulaki ye-USB yohlobo B1 ucezu
Ishubhu elifinyelayo ngokushisaIshubhu elifinyelayo ngokushisa40 mm
Ucingo LwesodaUcingo Lwesoda1 as required

Amathuluzi adingekayo:

Insimbi yokushiselaInsimbi yokushisela
Izandla ezisizayoIzandla ezisizayo
5

Check every wire

With the multimeter, check that each contact connects to the same contact at the other end and to no other, and that no contact touches a shell. Measure from shell to shell: the specification asks for less than 0.6 ohm.

Amathuluzi adingekayo:

Isilinganisi sikagesi esiyinhlanganiselaIsilinganisi sikagesi esiyinhlanganisela
6

Close the plugs

Clip the hoods over the plugs, slide the heat-shrink tubing over each joint between hood and cable, and shrink it with the heat gun as a strain relief.

Amathuluzi adingekayo:

Isibhamu somoya oshisayoIsibhamu somoya oshisayo
7

History and honest limits

The specification's revision history dates USB 1.0 to 15 January 1996, 1.1 to 23 September 1998 and 2.0, which added high speed, to 27 April 2000. The specification requires a standard detachable cable to end in OVERMOLDED plugs; ours has hand-soldered plugs in hoods, so it is not a compliant cable. We do not measure its 90 ohm impedance or its delay. The 1.5 m length, the 24 AWG power pair and the strip lengths are ours. How the plugs and the cable are made is not covered (unknown heads).