Bathroom Scale: Four Flat Load Cells Between Two Plates (Angel, 1991)

A floor scale only as thick as two plates. Four flat load cells sit in the corners between a base and a top plate; their strain gauges are wired into one bridge, so the signal is the sum of the four loads wherever you stand. Result: a low digital bathroom scale reading in pounds or kilograms. The patent gives under 0.05 % non-linearity, hysteresis and non-repeatability, and under 0.1 % error from off-centre loads; its feet let it stand on thick carpet. Source: S. Angel, US Patent 4,993,506 (1991). Unknown: the plate material and size, the maximum load, and the circuit. Ours: ebonite for the hard rubber, epoxy, the amplifier and display parts. Picture: patent drawing (Fig. 5).
Avançado
2 days

Instruções

1

Mount the four load cells

Put one load cell in each corner of the rigid base plate. Screw each one down to small flat raised pads on the plate. Place the pads away from the edge of the cell's beam, so that fixing the cell does not change its sensitivity. Under each cell, tap two holes through the base for the overload screws. Not given: the plate material and size.

Materiais para este passo:

Célula de cargaCélula de carga4 peças
Base e prato superior da balançaBase e prato superior da balança1 base and top plate
Parafusos de máquinaParafusos de máquina8 cell screws

Ferramentas necessárias:

Jogo de machos e cossinetesJogo de machos e cossinetes
Conjunto de chaves de fendasConjunto de chaves de fendas
Dimensões desconhecidasDimensões desconhecidas
2

Wire one bridge and the readout

Each cell's two gauges are half a Wheatstone bridge. Join the four halves into one full bridge, one half at each corner, so the bridge gives a signal in step with the sum of the four loads. The signal is amplified, turned into numbers by an analog-to-digital converter, worked into pounds or kilograms and shown on a display. Put the electronics and batteries in the space between the plates. Not given: the circuit. Ours: an op-amp and a segment LCD.

Materiais para este passo:

Circuito integrado amplificador operacionalCircuito integrado amplificador operacional1 amplifier
Conversor analógico-digitalConversor analógico-digital1 peça
Visor LCD de segmentosVisor LCD de segmentos1 peça
BateriaBateria1 as the circuit needs
Fio de ligaçãoFio de ligação1 as needed
Fio de soldaFio de solda1 a little

Ferramentas necessárias:

Ferro de soldarFerro de soldar
3

Fit the top plate on hard rubber pads

Glue four flat round pads of a rigid but slightly yielding material, such as hard rubber, under the top plate. Give each pad small round studs that snap into the two load holes of its cell, so the weight goes in at the centres of those holes. The pads soften impacts when something is dropped on the scale and take up sideways forces as the top plate bends. The snaps let the top plate be pulled off for repairs. Ours: ebonite and epoxy.

Materiais para este passo:

Vareta de eboniteVareta de ebonite1 four pads
Epóxi de dois componentesEpóxi de dois componentes1 a little

Ferramentas necessárias:

Serra de arco para metaisSerra de arco para metais
4

Fit the feet

Under the base, below each cell, fix a shallow foot of flexible material such as hard rubber, rounded underneath. Put its lowest point exactly below the centre of the cell's beam: the floor then pushes up at the beam's centre without bending it, and the scale works on thick carpet or uneven floors. Ours: ebonite.

Materiais para este passo:

Vareta de eboniteVareta de ebonite1 four feet
Epóxi de dois componentesEpóxi de dois componentes1 a little

Ferramentas necessárias:

Serra de arco para metaisSerra de arco para metais
5

Set the overload stops

Load the scale to its maximum capacity. Turn the short screws in from below until they just touch the arms of each cell's loading element, then lock them with adhesive. Any heavier load now rests on the screws instead of bending the cells further. Not given: the maximum capacity. Ours: calibration weights and epoxy.

Materiais para este passo:

Parafusos de máquinaParafusos de máquina8 overload screws
Epóxi de dois componentesEpóxi de dois componentes1 a little

Ferramentas necessárias:

Conjunto de pesos de calibraçãoConjunto de pesos de calibração
Conjunto de chaves de fendasConjunto de chaves de fendas

Materiais

11

Ferramentas necessárias

6

Blueprints relacionados

Estes blueprints compartilham conhecimento — técnicas, materiais ou princípios

CC0 Domínio Público

Este blueprint é liberado sob CC0. Você é livre para copiar, modificar, distribuir e usar este trabalho para qualquer finalidade, sem pedir permissão.

Apoie o Maker comprando produtos através do Blueprint, onde ele ganha uma Comissão Maker definida pelos vendedores, ou crie uma nova versão deste Blueprint e inclua-o como conexão no seu próprio Blueprint para compartilhar receita.

Discussão

(0)

Entrar para participar da discussão

Carregando comentários...