ARTE
BELEZA E BEM-ESTAR
ARTESANATO
CULTURA E HISTÓRIA
ENTRETENIMENTO
MEIO AMBIENTE
COMIDA E BEBIDAS
ENGENHARIA REVERSA
CIÊNCIAS
ESPORTES
TECNOLOGIA
TECNOLOGIA VESTÍVEL

Multi-Conductor Cable: Cotton-Covered, Waxed and Twisted
A cable of several insulated wires in one bundle, such as the four leads of a strain-gauge bridge. Each copper wire is wrapped in cotton thread and soaked in beeswax, then the wires are twisted together and covered again.
Iniciante
An afternoon
Instruções
1
1
Cut the conductors
Cut the conductors
Cut one copper wire per conductor (four for a bridge), a little longer than the cable.
Materiais para este passo:
Fio de cobre4 lengthFerramentas necessárias:
Descarnador de fios2
2
Wrap each wire in cotton
Wrap each wire in cotton
Clamp one end in the vise and the other in the hand drill's chuck, keeping it taut. Wind cotton thread on in a close spiral with no gaps, then a second layer the opposite way.
Materiais para este passo:
Linha de algodão1 as requiredFerramentas necessárias:
Torno de bancada
Berbequim de mão
Tesoura3
3
Soak in beeswax
Soak in beeswax
Melt beeswax in a double boiler and draw each covered wire slowly through it. Wipe off the excess and let it set.
Materiais para este passo:
Cera de abelha1 as requiredFerramentas necessárias:
Banho-maria
Placa de aquecimento4
4
Twist them together
Twist them together
Lay the covered wires side by side, clamp one end and twist them together evenly with the drill.
Ferramentas necessárias:
Torno de bancada
Berbequim de mão5
5
Cover the bundle
Cover the bundle
Wind an outer layer of cotton over the twisted bundle and wax it again.
Materiais para este passo:
Linha de algodão1 as required
Cera de abelha1 as requiredFerramentas necessárias:
Torno de bancada
Banho-maria
Placa de aquecimento6
6
Test it
Test it
Strip the ends. With a multimeter check each wire end to end, and check that no two wires touch.
Ferramentas necessárias:
Descarnador de fios
Multímetro7
7
Limits
Limits
Cotton insulation is only good for low temperatures, up to about 105 °C (Wikipedia, Magnet wire), and for dry places and low voltages such as instrument leads. The method is general workshop practice, ours.
Materiais
3- 4 lengthReferência
- 2 as requiredReferência
- 2 as requiredReferência
Este projeto faz
CC0 Domínio Público
Este blueprint é liberado sob CC0. Você é livre para copiar, modificar, distribuir e usar este trabalho para qualquer finalidade, sem pedir permissão.
Apoie o Maker comprando produtos através do Blueprint, onde ele ganha uma Comissão Maker definida pelos vendedores, ou crie uma nova versão deste Blueprint e inclua-o como conexão no seu próprio Blueprint para compartilhar receita.