Ferrite Toroid Core: Magnesium-Zinc Ferrite Reheated 18 h at 1000 °C and 20 h at 750 °C (Snoek 1948, Ex. III)

Snoek's magnesium-zinc ferrite ring (Example III), fired at 1400 °C and then given a second long treatment in oxygen: 18 hours at 1000 °C and 20 hours at 750 °C. He measured how its losses change with frequency, but gives no permeability for the reheated core. Source: J. L. Snoek, US 2,452,529 (Philips, 1948), Example III. Picture: our diagram.
高级
3 days

说明

1

Weigh 28 : 18 : 54 mol %

Mix 28 mol % magnesium oxide, 18 mol % zinc oxide and 54 mol % ferric oxide. Ours, by weight: 10.06 g magnesium oxide, 13.06 g zinc oxide and 76.88 g ferric oxide per 100 g.

此步骤所需材料:

氧化镁氧化镁10.06 克
氧化锌粉末氧化锌粉末13.06 克
氧化铁氧化铁76.88 克

所需工具:

等臂天平等臂天平
防尘口罩防尘口罩
2

Grind 30 hours in an iron mill

Grind the mixture for 30 hours in an iron ball mill.

所需工具:

铁球磨机铁球磨机
防尘口罩防尘口罩
3

Mould a ring at 4 tons per cm²

Mould the powder at 4 tons per square centimetre into a ring 3 cm across with a 4 × 4 mm section.

所需工具:

液压机液压机
环形压制模环形压制模
防尘口罩防尘口罩
4

Fire 2 hours at 1400 °C, cool 5–10 °C a minute

Heat the ring in oxygen for 2 hours at 1400 °C and cool it slowly in oxygen at 5 to 10 °C per minute.

所需工具:

管式炉管式炉
氧氧
高压气瓶高压气瓶
高温计高温计
坩埚钳坩埚钳
耐热手套耐热手套
5

Reheat: 18 hours at 1000 °C, 20 hours at 750 °C

Heat the cooled core to 1000 °C and hold it there for 18 hours, then at 750 °C for 20 hours, and cool slowly again, all in oxygen. Snoek shows the resulting losses only as a curve; he gives no permeability for it.

所需工具:

管式炉管式炉
氧氧
高压气瓶高压气瓶
高温计高温计
坩埚钳坩埚钳
耐热手套耐热手套