Samvinna
LIST
FEGURÐ OG VELLÍÐAN
HANDVERK
MENNING OG SAGA
SKEMMTUN
UMHVERFI
MATUR OG DRYKKUR
ÖFUGVERKFRÆÐI
VÍSINDI
ÍÞRÓTTIR
TÆKNI
KLÆÐANLEG TÆKNI

Lead-Lined Tank: a Steel Acid Tank with an Antimonial Lead Lining (Bell, 1923)
A riveted steel tank lined with sheet lead, for weak sulphuric acid, which eats bare steel. The lead hangs from the top angle and is held to the shell by steel straps covered with lead burned to the lining.
Bell's example (Fig. 170) is a vertical tank 15 ft across and 10 ft high, lined with 6 % antimony lead at 7 1/2 lb per sq ft.
Source: H. S. Bell, American Petroleum Refining (1923), pp. 305-306. Picture: Fig. 170 of the book.
Sérfræðingur
Unknown
Leiðbeiningar
1
1
Build the steel tank
Build the steel tank
Build the shell as a standard riveted vertical tank, with plate at least 3/8 in thick. Drive the rivets with flat heads 1/16 to 1/8 in high inside, and leave out an occasional rivet so leaks in the lining can be found. The shell plates need not be bevelled or caulked. If you can, stand it on concrete piers with steel I-beams so the bottom can be inspected, and protect the concrete with coal tar or petroleum pitch.
Efni fyrir þetta skref:
Plata úr mjúku stáli1 3/8 in min.
Stálhnoð1 stykkiNauðsynleg verkfæri:
Hnoðhamar
Koltjörubik
Óþekkt mál2
2
Cut the lead
Cut the lead
Use chemical lead at 8 lb per sq ft, or 6 % antimony lead at 7 1/2 lb per sq ft. For Bell's 15 x 10 ft tank: 7 sheets 10 ft 11 in x 7 ft 2 in, 7 sheets 10 ft 11 in x 7 in, and 2 half-circle sheets of 8 ft radius for the bottom.
Efni fyrir þetta skref:
Blýþynna16 sheets, 6 % antimony, 7 1/2 lb/sq ftNauðsynleg verkfæri:
Plötuklippur3
3
Hang and strap the lining
Hang and strap the lining
Dress the lead over the top angle to carry it. Hold it to the shell with straps of round-edged tire steel (Fig. 170: seven straps 2 1/2 x 3/8 in, about 9 ft long), no more than 8 ft apart round the shell; round edges won't cut the lead while it is dressed. Bolt the straps through the shell with 1/2 in bolts, heads countersunk inside.
Efni fyrir þetta skref:
Flatstál úr mjúku stáli7 2 1/2 x 3/8 in, about 9 ft
Sexkantbolti - flokkur 8.81 1/2 in, number not givenNauðsynleg verkfæri:
Trésleggja4
4
Burn the seams and cover the straps
Burn the seams and cover the straps
Burn (fuse) the lead seams together. Burn a narrow strip of lead over each strap onto the lining, so no steel or bolt head is left bare to the acid. Not given: the burning tool.
Efni fyrir þetta skref:
Blýþynna1 cover stripsNauðsynleg verkfæri:
BlysEfni
5- 1 3/8 in min.Staðgengill
- 1 stykkiStaðgengill
- 1 cover stripsStaðgengill
- 7 2 1/2 x 3/8 in, about 9 ftStaðgengill
- 1 1/2 in, number not givenStaðgengill
Nauðsynleg verkfæri
6- Staðgengill
- Staðgengill
- Staðgengill
- Staðgengill
- Staðgengill
- Staðgengill
Efni úr tengdum teikningum
Þessi teikning býr til
CC0 opinbert ríki
Þessi teikning er gefin út undir CC0. Þér er frjálst að afrita, breyta, dreifa og nota þetta verk í hvaða tilgangi sem er, án þess að biðja um leyfi.
Studdu smiðinn með því að kaupa vörur í gegnum teikningu hans þar sem hann fær þóknun smiða sem seljendur ákvarða, eða búðu til nýja endurskoðun á þessari teikningu og tengdu hana sem tengingu í þinni eigin teikningu til að deila tekjum.