Electronic Baby Scale That Holds a Steady Reading: Hino & Itani, 1981
Masamichi Hino and Seiichi Itani of Kubota Ltd., Osaka, patented this electronic weighing apparatus in 1981, US 4,285,411. A strain-gauge load cell barely moves, so a baby on the pan is not frightened, but babies seldom lie still and the displayed weight keeps changing. Here the scale keeps showing each new reading until it has stopped changing, then holds that weight on a four-digit display until the baby is lifted off. The patent names baby scales in hospitals, and also price computing scales.
고급
Factory process
안내
1
1
Pan and load cell
Pan and load cell
Couple the article placing pan, such as a basket for a baby, mechanically to a strain-gauge load cell in the casing. The load cell gives an analog voltage that follows the weight on the pan; an amplifier, its gain set by a variable resistor, raises it.
이 단계의 재료:
저울 케이스1 개
계량 접시1 개
로드셀1 개
로드셀 증폭기1 개
가변저항기1 개
배선용 전선1 as required
땜납 선1 as required필요한 도구:
전기 납땜인두2
2
Convert to digital
Convert to digital
An analog-to-digital converter turns the amplified voltage into digital data at each pulse from a timing pulse generator.
이 단계의 재료:
아날로그-디지털 변환기1 개
타이밍 펄스 발생기1 개필요한 도구:
전기 납땜인두3
3
Span adjustment
Span adjustment
Pass the data through a digital multiplier. Set the variable resistor so the span is slightly too large, then set a multiplier below 0.9999 on the numerical value setting switch (its two upper digits are fixed at 9, the two lower ones are set) until a known rated weight on the pan reads correctly. The resistor gives the coarse adjustment, the switch the fine one; digital multiplication is not upset by temperature or humidity.
이 단계의 재료:
디지털 곱셈기1 개
수치 설정 스위치1 개필요한 도구:
전기 납땜인두
추4
4
Stable-state detector
Stable-state detector
Feed the data into three registers in cascade that shift it on at each timing pulse, so they hold the three previous readings. A coincidence detecting circuit (exclusive-NOR and AND gates) gives a high output when the newest reading equals all three: the weight is steady. (A second version subtracts the previous reading from the newest and calls it steady when the difference is within a set value, which may be zero.)
이 단계의 재료:
디지털 데이터 레지스터3 개
일치 검출 회로1 개필요한 도구:
전기 납땜인두5
5
Hold the reading
Hold the reading
Load the display buffer with each new reading through an inhibit gate. When the detector reports a steady weight, it sets a J-K flip-flop; the flip-flop's output, through an OR gate, closes that inhibit gate, so the buffer keeps the steady weight even if the baby moves. A digital comparator checks each new reading against a reference value, for example 2 grams: when the baby is lifted off and the reading falls to it, the flip-flop resets and the display follows the new readings again. No button is needed to release the hold.
이 단계의 재료:
디스플레이 버퍼1 개
J-K 플립플롭1 개
논리 게이트3 개
디지털 비교기1 개
기준값 설정 회로1 개필요한 도구:
전기 납땜인두6
6
Display and switches
Display and switches
Drive a four-digit display of seven-segment numerals from the buffer through a segment decoder. Fit two switches outside the casing: one keeps the flip-flop reset, so the newest weight is always shown; the other starts a timer that freezes the display for a set time, say eight seconds, so the weight can be read and written down without a mistake.
이 단계의 재료:
7세그먼트 디스플레이 드라이버1 개
4자리 7세그먼트 디스플레이1 개
전원 스위치2 개
디스플레이 홀드 타이머1 개필요한 도구:
전기 납땜인두재료
22- 1 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 플레이스홀더
- 1 as required플레이스홀더
- 1 as required플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 3 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 3 개플레이스홀더
- 1 개플레이스홀더
- 1 개플레이스홀더
- 플레이스홀더
- 플레이스홀더
- 2 개플레이스홀더
- 1 개플레이스홀더
이 블루프린트로 만드는 것
관련 블루프린트
이 블루프린트들은 지식을 공유합니다 — 기술, 재료 또는 원리
CC0 퍼블릭 도메인
이 블루프린트는 CC0로 공개되었습니다. 어떤 목적으로든 자유롭게 복사, 수정, 배포 및 사용할 수 있습니다.