Shunts and Multipliers: One Movement, Every Range

A moving-coil movement reads full scale at a milliamp or less. Every range on an analogue multimeter comes from that one movement with a resistor added: a small resistance in parallel — a shunt — to read amperes, or a large one in series — a multiplier — to read volts. The resistors are easy to calculate. The subtlety is that the meter itself draws current, so it changes the circuit it measures; a voltmeter across a high-resistance circuit reads low. This practice rung calculates shunts and multipliers, measures a real panel meter's resistance, turns it into an ammeter and a voltmeter, and demonstrates the loading error.
초급
About 3 hours

안내

1

Shunts, multipliers and loading

Jupyter 노트북 불러오는 중…
2

Measure your meter's own resistance

Connect the panel meter in series with a variable resistor (a potentiometer) and a 1.5 V cell, and adjust for exactly full-scale deflection. Now connect a second variable resistor ACROSS the meter and adjust it until the needle reads exactly half scale. Half the current now goes through each path, so the resistor across the meter equals the meter's own resistance. Disconnect it and measure it with the multimeter: that is R_m. Put it, and the full-scale current from the meter's dial, into the notebook.

이 단계의 재료:

가동 코일형 패널 계기가동 코일형 패널 계기1 개
가변저항기가변저항기2 개

필요한 도구:

멀티미터멀티미터
악어클립 시험선악어클립 시험선
3

Make an ammeter and a voltmeter

For a 10 V voltmeter, choose resistors from the kit that add up to the notebook's multiplier value, put them in series with the meter, and check the reading against the multimeter on a battery or the bench supply. For a 1 A ammeter, cut the notebook's length of copper wire (about 2.3 m of 0.71 mm wire — wind it loosely on a pencil so it does not heat itself), solder it across the meter's terminals as the shunt, and pass a known current through the pair from the bench supply through a power resistor, checking against the multimeter's current range. Trim the wire until the readings agree. Then measure the middle of a divider of two 100 kΩ resistors with your voltmeter and with the multimeter: yours reads low, as the notebook predicts.

이 단계의 재료:

저항 키트저항 키트1 세트
구리선구리선1 미터
주석-납 땜납주석-납 땜납10 g
Power Resistor Kit - 10W (25 pack)Power Resistor Kit - 10W (25 pack)1 팩

필요한 도구:

멀티미터멀티미터
직류 전원 장치직류 전원 장치
인두인두
디지털 캘리퍼스 6인치디지털 캘리퍼스 6인치
4

Context

A practice rung: shunts and multipliers came with the moving-coil meter of the previous rung and turned one movement into a multi-range instrument. The resistance per volt of a meter became its quality mark. **Honest limits.** Copper shunts drift with temperature (manganin does not). Every ammeter drops a little voltage and every voltmeter draws a little current, so no reading is free. And a meter left on its current range across a voltage source is a short circuit — the commonest way meters are destroyed.

재료

6

필요 도구

5
예상 총액
만든 사람이 산 것. 가격이 없는 재료는 구매하는 곳에서 구하면 됩니다.