The Plate Heat Exchanger: Thin Plates, Turbulence, and a Frame You Can Open
Emma

Зохиогч

Emma

27. Есдүгээр сар 2026SE
15
0
0
0
0

The Plate Heat Exchanger: Thin Plates, Turbulence, and a Frame You Can Open

A stack of thin pressed-metal plates, each sealed to the next by a gasket round its edge, clamped between two heavy frame plates by long bolts. Hot and cold liquids flow in alternate gaps, so every plate has hot on one face and cold on the other. Richard Seligman's plate heat exchanger of 1923, made by his Aluminium Plate & Vessel Company (APV), was built for the dairy: milk had to be heated and cooled quickly for pasteurisation, and the equipment had to come apart for cleaning every day. Thin corrugated plates give very high heat transfer in a small space; the gasketed frame opens with a spanner. This rung works out where the size advantage comes from, and builds a two-channel plate exchanger from copper sheet, printed gaskets and a clamped frame.
Дунд шат
About 6 hours

Зааварчилгаа

1

Where the high U comes from, and what fouling costs

Jupyter дэвтэр ачаалж байна…
2

Plate exchangers run in counterflow

A plate exchanger's ports are arranged so the two liquids run in opposite directions through alternate gaps. The embedded blueprint explains why, and measures it on a tube-in-tube exchanger.
3

Build a two-channel plate exchanger

Cut three copper sheets 150 × 100 mm. The middle one is the heat-transfer plate; the outer two are blanks. Print two gasket frames in TPU, 3 mm thick, each the outline of the plate with a 10 mm border, so each frame encloses a flow gap. Stack: acrylic end plate / copper blank / gasket frame / copper plate / gasket frame / copper blank / acrylic end plate. Drill four corner bolt holes through everything and clamp with threaded rod and wing nuts, tightening evenly. Drill and fit hose tails so that gap 1 is fed at the top-left and drains at the bottom-right, and gap 2 is fed at the bottom-right and drains at the top-left — counterflow across the plate. Add ridges to the gasket frames or press shallow chevrons into the copper with a blunt punch to break up the flow.

Энэ алхмын материал:

Зэсэн хуудасЗэсэн хуудас1 хуудас
Уян TPU судалУян TPU судал40 г
Акрилын хавтанАкрилын хавтан1 хуудас
Эрчилсэн савааЭрчилсэн саваа1 ширхэг
Далавчит гайкаДалавчит гайка4 ширхэг
ПВХ хоолойн холбогчийн иж бүрдэлПВХ хоолойн холбогчийн иж бүрдэл1 багц
Силиконон битүүлэгчСиликонон битүүлэгч1 ширхэг

Шаардлагатай багаж:

FDM 3D хэвлэгчFDM 3D хэвлэгч
Утасгүй өрөмУтасгүй өрөм
Өрмийн үзүүрийн иж бүрдэлӨрмийн үзүүрийн иж бүрдэл
ШугамШугам
Тохируулгатай түлхүүрТохируулгатай түлхүүр
Арьсан ажлын бээлийАрьсан ажлын бээлий
4

Test it, then open it

Run hot water through one gap and cold through the other at equal, timed flows, and read the four temperatures with the thermometer (or reuse the four-probe logger from the counterflow rung). Work out the heat carried by each side. Now the reason the design exists: undo the wing nuts, lift the stack apart and look. Any sediment, scale or film is on the copper where you can wipe it. Wipe, restack and tighten. An exchanger you can open is an exchanger you can keep clean — which in a dairy is the difference between a safe product and a spoiled one. Retighten evenly: a gasket squeezed harder on one side leaks on the other.

Энэ алхмын материал:

УсУс30 литр

Шаардлагатай багаж:

Шилэн цахилгаан данхШилэн цахилгаан данх
ХувинХувин
Хэмжих аягаХэмжих аяга
Секунд хэмжигчСекунд хэмжигч
Гал тогооны термометрГал тогооны термометр
Тохируулгатай түлхүүрТохируулгатай түлхүүр
5

History and context

**Richard Seligman, 1923** — the first commercially successful plate heat exchanger, made by the Aluminium Plate & Vessel Company he had founded in London in 1910, for the high-temperature short-time pasteurisation of milk. No patent number is asserted here: it could not be read from a primary source, and the design is fully documented. Plate exchangers now run in food, brewing, district heating, heat pumps and chemical plant; brazed versions with no gaskets at all are the small cube in many domestic boilers. **Honest limits.** Gaskets limit the temperature and pressure, and the chemicals they can meet. Narrow gaps clog on fibrous or particle-laden liquids, where shell-and-tube exchangers still win. And the high pressure drop of those turbulent gaps costs pumping power.

Материал

8

Шаардлагатай багаж

11

CC0 Нийтийн домэйн

Энэ загвар CC0 дор гаргагдсан. Та зөвшөөрөл авахгүйгээр хуулах, өөрчлөх, түгээх, ашиглах боломжтой.

Загвараар дамжуулан бүтээгдэхүүн худалдаж авч Бүтээгчийг дэмжээрэй Бүтээгчийн шимтгэл Борлуулагчаар тогтоосон, эсвэл энэ загварын шинэ хувилбар үүсгэж орлогоо хуваахын тулд өөрийн загварт холбоос болгон оруулна уу.

Хэлэлцүүлэг

(0)

Нэвтрэх хэлэлцүүлэгт нэгдэхийн тулд

Сэтгэгдлүүдийг ачаалж байна...