कला
सुन्दरता र कल्याण
हस्तकला
संस्कृति र इतिहास
मनोरञ्जन
वातावरण
खाना र पेय
रिभर्स इन्जिनियरिङ
विज्ञान
खेलकुद
प्रविधि
पहिर्न मिल्ने

Gel Filtration: Separating by Size Alone
Every separation in this batch so far works because molecules STICK to something — to chalk, to silica, to a grease film — and stick by different amounts. Gel filtration works because they stick to nothing at all.
Per Flodin and Jerker Porath, at Uppsala in 1959, made beads of cross-linked dextran riddled with pores of a controlled size. A small molecule wanders into every pore and takes a long, tortuous route through the column. A molecule too big to enter any pore is swept straight past, through the gaps between the beads only, and comes out FIRST.
That inversion is what makes it unique and slightly counter-intuitive: in gel filtration the biggest thing leaves first, and everything is off the column by the time one column volume has run through. It is also the gentlest separation there is — nothing binds, so nothing is denatured — which is why it is how a protein gets its buffer changed.
मध्यम
1 day
निर्देशनहरू
1
1
Swell the medium before it goes anywhere near the column
Swell the medium before it goes anywhere near the column
Stir the dry beads into several volumes of buffer and leave them for the time the supplier states — some grades need hours, some need boiling. Then let the slurry settle and pour off the fines that stay suspended.
Dry beads swell to many times their dry volume. Load them dry and they swell inside the tube, which either jams solid or cracks the bed. Removing the fines matters too: those tiny fragments pack into the spaces between proper beads and choke the flow to nothing, and they are the usual reason a home-packed column runs at a drip an hour.
यस चरणका सामग्री:
आकार-बहिष्करण क्रोमेटोग्राफी माध्यम25 ग्राम
खाने सोडा5 ग्रामचाहिने औजार:
बोरोसिलिकेट बिकर
डिजिटल तराजु2
2
Pour the bed in ONE go
Pour the bed in ONE go
Plug the outlet, part-fill the tube with buffer, and pour the whole slurry down a glass rod against the wall in a single continuous pour. Let it settle under its own weight with the outlet running slowly.
Pouring in stages is the classic ruin: each new layer settles onto a compacted one and leaves a visible horizontal line, and that line is a discontinuity every band has to cross. Never stir the settled bed to 'even it out' — you will grade the beads by size, fine at the top, which is worse than what you started with.
चाहिने औजार:
स्तम्भ क्रोमाटोग्राफी उपकरण सेट
प्रयोगशाला स्ट्यान्ड र क्ल्याम्प सेट3
3
Find the void volume with something far too big
Find the void volume with something far too big
Run a small load of a very large coloured molecule through and measure the volume of buffer collected before it appears. That is the void volume: the liquid in the gaps BETWEEN the beads.
Nothing can come out earlier than this, because nothing can travel faster than the buffer in the open channels. The void volume is the reference every other measurement on this column is made against, and it is worth measuring properly once rather than estimating it as a third of the bed volume — which is only approximately true and only for a well-packed column.
चाहिने औजार:
परीक्षण नली (बोरोसिलिकेट)
नाप अङ्कित पिपेट (मोर)4
4
Find the total volume with something tiny
Find the total volume with something tiny
Now run a small, freely diffusing coloured salt — copper sulfate is ideal, since its blue is easy to follow. It enters every pore and comes out last.
The volume at which it emerges is the total liquid volume of the column: the gaps plus all the pore space. Everything you will ever separate on this column emerges between these two numbers, and that is the whole working range. Unlike every other method in this batch, the run has a hard end — there is no 'wait longer and it will come off', because nothing is stuck.
यस चरणका सामग्री:
कपर सल्फेट (प्रयोगशाला श्रेणी)5 ग्रामचाहिने औजार:
परीक्षण नली (बोरोसिलिकेट)
नाप अङ्कित पिपेट (मोर)
बोरोसिलिकेट बिकर5
5
Separate a dye from a salt, and watch the order invert
Separate a dye from a salt, and watch the order invert
Load a mixture of a large dye and copper sulfate together in the smallest volume you can manage, and collect fractions.
The dye leaves first even though it is far heavier — which is the moment the method stops being abstract. Then note the practical rule this demonstrates: load volume must be SMALL, ideally under 2% of the bed. There is no focusing effect here to sharpen a wide band, because nothing binds and re-releases. Whatever width you load, you get back plus some spreading.
यस चरणका सामग्री:
खानेकुराको रङ1 बोतल
कपर सल्फेट (प्रयोगशाला श्रेणी)5 ग्रामचाहिने औजार:
परीक्षण नली (बोरोसिलिकेट)
नाप अङ्कित पिपेट (मोर)6
6
Use it the way laboratories actually use it: buffer exchange
Use it the way laboratories actually use it: buffer exchange
Equilibrate the column in the buffer you WANT, load your sample in whatever buffer it is in, and collect the large component as it comes off.
It leaves in the new buffer, and the old salts trail out far behind it. In two column volumes and about twenty minutes you have changed a protein's environment completely without ever binding it to anything — no acid, no salt gradient, no heat. This one application, called desalting, is probably more common in working laboratories than the size measurement the method is named for.
यस चरणका सामग्री:
खाने सोडा5 ग्रामचाहिने औजार:
परीक्षण नली (बोरोसिलिकेट)
बोरोसिलिकेट बिकर7
7
Calibrating the column into a molecular ruler
Calibrating the column into a molecular ruler
Jupyter नोटबुक लोड हुँदैछ…
चाहिने औजार:
नाप अङ्कित पिपेट (मोर)8
8
Regenerate the bed rather than repacking it
Regenerate the bed rather than repacking it
Wash two column volumes of buffer through after every run, and store the column with a preservative or in the refrigerator.
Because nothing binds, a gel filtration column is essentially self-cleaning and will run for years — the medium is the expensive part and it does not wear out. What kills a column is microbial growth in a bed left wet and warm, and air drawn into the top when a reservoir runs dry. Both are avoidable, and both mean repacking, which is the one job on this column nobody enjoys twice.
चाहिने औजार:
बोरोसिलिकेट बिकरसामग्री
4- प्लेसहोल्डर
- 5 ग्रामप्लेसहोल्डर
- प्लेसहोल्डर
- 1 बोतलप्लेसहोल्डर
सम्बन्धित ब्लुप्रिन्ट
यी ब्लुप्रिन्टहरूले ज्ञान साझा गर्छन् — प्रविधि, सामग्री वा सिद्धान्त
CC0 सार्वजनिक डोमेन
यो ब्लुप्रिन्ट CC0 अन्तर्गत जारी गरिएको छ। तपाईं अनुमति नसोधी प्रतिलिपि, परिमार्जन, वितरण र प्रयोग गर्न सक्नुहुन्छ।
ब्लुप्रिन्ट मार्फत उत्पादनहरू किनेर सिर्जनाकर्तालाई सहयोग गर्नुहोस् सिर्जनाकर्ता कमिसन विक्रेताले तोकेको, वा यो ब्लुप्रिन्टको नयाँ संस्करण बनाउनुहोस् र आम्दानी बाँड्न आफ्नो ब्लुप्रिन्टमा जडानको रूपमा समावेश गर्नुहोस्।