The Solenoid Valve: An Electromagnet That Opens a Pipe
A relay lets a small current switch a large one. A solenoid valve does the same for a fluid: a coil round a tube pulls a soft-iron plunger that opens or closes an orifice, so a switch, a thermostat or a timer can turn water, air, gas or oil on and off without a hand on the valve. Washing machines, irrigation timers, compressors and boilers all use them.
The Automatic Switch Company (ASCO) of New York is credited with making the first solenoid valves in 1910.
This rung works out why a solenoid's pull depends so steeply on its air gap, why that limits a direct-acting valve's orifice, and how a pilot valve gets round it — then drives a real 12 V valve from a switch and measures when it will and will not open.
Początkujący
About 3 hours
Instrukcje
1
1
Pull against gap, and the orifice it can open
Pull against gap, and the orifice it can open
Wczytywanie notatnika Jupyter…
2
2
The same electromagnet, switching a current
The same electromagnet, switching a current
A solenoid valve is an electromagnet pulling an armature, as in a relay. The embedded blueprint builds the relay the idea came from.
3
3
Measure a solenoid's pull against its gap
Measure a solenoid's pull against its gap
Take a small 12 V push-pull solenoid. Clamp it upright and hang its plunger from a spring scale, with a nut on the scale's hook so you can set the gap between the plunger's end and the coil's stop with feeler gauges.
At each gap switch the coil on from the power supply and read the pull. Plot pull against gap: it rises steeply as the gap closes, as the notebook's $1/g^2$ says, then levels off as the iron saturates. Watch the coil current on the supply's meter: it does not change with the gap — the current sets the ampere-turns, the gap sets the pull.
Materiały do tego kroku:
Elektromagnes liniowy1 sztuka
Przewody połączeniowe1 sztukaPotrzebne narzędzia:
Zasilacz prądu stałego
Siłomierz (waga sprężynowa)
Zestaw szczelinomierzy
Imadło warsztatowe
Multimetr4
4
Drive a real valve, and find where it stops opening
Drive a real valve, and find where it stops opening
Plumb a 12 V solenoid valve between a garden hose (through a ball valve and pressure gauge) and an open outlet into a bucket, with the valve's arrow pointing downstream. Wire the coil to the power supply through a push button.
Press the button and water flows; release it and it stops. Now close the ball valve until the gauge reads almost nothing and try again: many small 12 V valves are pilot-operated and will not open at all at very low pressure — they need a pressure difference to lift their diaphragm. Note the lowest pressure at which it opens, and check the valve's plate or data sheet for its minimum operating pressure.
Materiały do tego kroku:
12V Solenoid Valve - 19mm1 sztuka
Wąż ogrodowy1 sztuka
Zawór kulowy mosiężny1 sztuka
Taśma uszczelniająca PTFE do gwintów1 sztuka
Przycisk1 sztuka
Woda20 litrówPotrzebne narzędzia:
Zasilacz prądu stałego
Manometr
Klucz nastawny
Wiadro5
5
A solenoid valve that will not behave
A solenoid valve that will not behave
Solenoid valve faults in the order to check them.
Flow
Loading...
6
6
History and honest limits
History and honest limits
The **Automatic Switch Company** (ASCO), founded in New York, is credited with the first solenoid valves, in 1910. Direct-acting and pilot-operated valves of every size now follow the same two patterns.
**Honest limits.** The notebook's pull formula counts only the air gap and ignores the iron's own reluctance and leakage flux; real solenoids give less. A coil held on continuously warms, and its resistance and pull fall as it does. Never use a water valve for gas or fuel: those need valves certified for them.
Materiały
8- od$4.97
- od$1.60
- 12V Solenoid Valve - 19mm10% prowizji1 sztuka$7.49
- Wąż ogrodowy10% prowizji1 sztukaZastępnik
- 1 sztukaZastępnik
- Zastępnik
- 20 litrówZastępnik
Wymagane narzędzia
8- Zastępnik
- Zastępnik
- Zastępnik
- Zastępnik
- Zastępnik
- Zastępnik
- Zastępnik
- Zastępnik
Szacowany koszt
To, co kupił twórca. Materiały bez ceny kupujesz tam, gdzie je znajdziesz.
Powiązane blueprinty
Te blueprinty dzielą się wiedzą — technikami, materiałami lub zasadami

The Telegraph Relay
autor: Ed
Elektronika
43
0
0
0
2
0

The Float Valve
autor: Martin
TECHNOLOGIA
34
0
0
0
1
0

One Way Only: The Check Valve and the Bang It Makes
autor: Martin
Narzędzia
11
0
0
0
0
0

The Spool Valve: Steering Oil With a Sliding Rod
autor: Emma
Mechanika
6
0
0
0
0
0

Ohm's Law at the Bench: Picking the Resistor That Saves the LED
autor: Volt
Elektronika
23
0
0
0
0
0
CC0 Domena publiczna
Ten plan jest udostępniany na licencji CC0. Możesz go swobodnie kopiować, modyfikować, rozpowszechniać i wykorzystywać do dowolnych celów, bez konieczności uzyskiwania zgody.
Wesprzyj Makera kupując produkty przez jego plan, za co zarabia Prowizja Makera ustalony przez sprzedawców, lub stwórz nową iterację tego planu i dołącz go jako połączenie w swoim własnym planie, aby dzielić się przychodami.