Adhesion: Four Tests, and Three of Them Destroy the Part
A plated part that looks perfect and a plated part that will peel next month are indistinguishable by eye. Adhesion has to be tested, and every worthwhile test destroys the piece it is performed on.
So the standard practice is to plate a **test coupon** alongside the real work, from the same batch, through the same baths, and to destroy that instead. A coupon costs a scrap of steel and answers the only question that matters.
The tests are simple, they need no equipment, and the failure modes each point at a different mistake earlier in the process.
Trung cấp
2 hours
Hướng dẫn
1
1
The bend test and the burnish test
The bend test and the burnish test
**The bend test.** Bend the coupon through 180 degrees over a mandrel of a few times its thickness, then examine the outside of the bend under magnification.
A well-adhered coating **cracks with the substrate** — it may craze, but the pieces stay attached, because the coating and the metal are failing together.
A poorly adhered coating **lifts, flakes or peels away from the bend**, often in a sheet. That is a clean separation at the interface, and it means the surface was not clean.
**The burnish test.** Rub a small area briskly with a smooth hard tool — the back of a knife, a burnisher — for fifteen seconds. A well-adhered coating polishes. A poorly adhered one blisters, because the friction works it loose from underneath.
**The file test.** File across the edge of the coupon at 45 degrees, from the substrate towards the coating. A good coating is cut through cleanly; a bad one lifts ahead of the file.
**Look at the WAY it failed.** A coating that lifts in large sheets with a shiny back was on a greasy surface. One that lifts in small flakes with a dull grey back was on an oxidised one. The fracture surface names the cause.
Vật liệu cho bước này:
Tấm thép mềm2 cái
Tấm niken1 cáiCông cụ cần thiết:
Kính lúp thợ kim hoàn2
2
Thermal shock, which finds what the others miss
Thermal shock, which finds what the others miss
**Heat the part and quench it.** The coating and the substrate expand by different amounts, so a sudden temperature change puts a large shear stress directly on the interface — which is exactly what an adhesion test wants to do.
Typical: 150 to 300 C for an hour, depending on the substrate, then straight into cold water. Blistering or peeling afterwards is a fail.
**It is the most searching of the tests**, because it stresses the whole area at once rather than one line, and it finds marginal adhesion that a bend test passes.
**It doubles as the hydrogen bake.** Heating plated high-strength steel to 190 to 220 C for several hours drives dissolved hydrogen out before it can cause delayed brittle fracture, and it must be done within hours of plating. A part that both bakes and survives the quench has answered two questions.
**Do not thermal-shock a part that has been hardened**, unless the temperature is safely below its tempering temperature. The test would ruin the part in a different way.
**Record which test was used** alongside the result. "Passed adhesion" means nothing without it, in the same way that a purity figure means nothing without its method.
Vật liệu cho bước này:
Tấm thép mềm2 cáiCông cụ cần thiết:
Nhiệt kế phòng thí nghiệm
Cốc thuỷ tinh borosilicat
Găng tay chống hóa chất3
3
Why adhesion fails, in order of likelihood
Why adhesion fails, in order of likelihood
**Contamination.** Oil, grease, a fingerprint, polishing compound, or drag-in from a previous bath. This is the great majority of failures, and the water-break test would have caught it.
**Oxide.** The part was pickled, then stood in air, then plated. A clean steel surface re-oxidises visibly in minutes and invisibly in seconds.
**Passivity.** Some metals — stainless steel, aluminium, titanium, chromium — carry an oxide film that re-forms faster than it can be removed. They need a specific activation step: a **Wood's nickel strike** for stainless, a zincate for aluminium. Plating them directly always fails, however clean they are.
**Interrupted current.** If the current stops mid-plate and then restarts, the surface passivates in the gap and the second layer does not bond to the first. A bath that has lost power is stripped and restarted, not resumed.
**Internal stress.** A highly stressed deposit — bright nickel with too much brightener, or chromium, which is always in tension — pulls itself off a marginal bond. It can peel weeks later with nothing else having changed.
**Dissimilar expansion.** A thick hard coating on a substrate with a very different expansion coefficient, in service across a temperature range.
The first two account for most of it, and both are preparation.
Vật liệu cho bước này:
Tấm thép mềm1 cái
Tấm niken1 cáiCông cụ cần thiết:
Kính lúp thợ kim hoàn4
4
Stripping and starting again
Stripping and starting again
A failed coating has to come off completely before another can go on, and a partially stripped part plates worse than a bare one.
**Chemical stripping** is the usual route and it is specific to the pair of metals. The requirement is a solution that dissolves the coating and does not attack the substrate — which is exactly the opposite of the plating chemistry, and is why a strip for nickel-on-steel is not a strip for nickel-on-brass.
**Reverse-current stripping** makes the part the anode and dissolves the coating off electrochemically. Controllable, and it stops when the coating is gone if the solution is chosen so the substrate passivates.
**Mechanical stripping** — blasting, grinding — always removes some substrate and changes the dimensions. It is the last resort on a precision part and the first choice on a rough one.
**Then start from the beginning.** A stripped part goes back through mechanical preparation, degreasing and pickling, not straight into the plating tank. The stripping solution is itself contamination.
**Consider whether it is worth it.** Stripping and replating a small part often costs more than the part. The decision is easier with a test coupon, because the failure is discovered on the coupon rather than after the part is assembled into something.
Vật liệu cho bước này:
Axit clohydric pha loãng 10 %1 cái
Tấm thép mềm1 cáiCông cụ cần thiết:
Cốc thuỷ tinh borosilicat
Nguồn điện bàn điều chỉnh được
Găng tay chống hóa chất
Kính chống hóa chất bắnVật liệu
3- 2 cáiTạm thời
- 1 cáiTạm thời
- Tạm thời
Công cụ yêu cầu
6- Tạm thời
- Tạm thời
- Tạm thời
- Tạm thời
- Tạm thời
- Tạm thời
Blueprint liên quan
Các blueprint này chia sẻ kiến thức — kỹ thuật, vật liệu hoặc nguyên tắc
CC0 Phạm vi công cộng
Bản thiết kế này được phát hành theo CC0. Bạn tự do sao chép, sửa đổi, phân phối và sử dụng cho bất kỳ mục đích nào mà không cần xin phép.
Hỗ trợ nhà sáng tạo bằng cách mua sản phẩm qua bản thiết kế, nơi họ nhận Hoa hồng nhà sáng tạo do nhà bán hàng đặt, hoặc tạo phiên bản mới và kết nối trong bản thiết kế riêng để chia sẻ doanh thu.